Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
CAGE Information
Code | Company |
---|---|
30890 | INTERLINK COMMUNICATIONS INC |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE TWO ROWS |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE TWO ROWS |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 50.0 OHMS SINGLE SECTION |
AAPN | SECTION QUANTITY | 1 |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AXGY | MOUNTING METHOD | TERMINAL |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0/+20.0 SINGLE SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
AEDZ | SHAFT BEARING TYPE | SLEEVE |
ADAQ | BODY LENGTH | 0.230 INCHES MINIMUM AND 0.260 INCHES MAXIMUM |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AAQL | BODY STYLE | RECTANGULAR |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 240.0 NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 260.0 NOMINAL |
ABJT | TERMINAL LENGTH | 0.250 INCHES MINIMUM AND 0.374 INCHES MAXIMUM |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
ABPM | BODY DIAMETER | 0.280 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0/+100.0 SINGLE SECTION |
ADAT | BODY WIDTH | 0.280 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.350 INCHES MINIMUM AND 0.370 INCHES MAXIMUM |