Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
20284 TARGET CORPORATION DBA TARGET

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CRBZ WINDING OPERATING CURRENT 3.968 AMPERES NOMINAL B SINGLE COMPONENT SINGLE SECONDARY
AKPV MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 0.969 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.031 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
TEST TEST DATA DOCUMENT 81349-MIL-T-27 SPECIFICATION
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 4.950 OUNCES
ACZF MAXIMUM TRANSFORMER POWER RATING 25.0 VOLT-AMPERE SINGLE COMPONENT
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AEHZ MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS
TTQY TERMINAL TYPE AND QUANTITY 6 FEED THRU
CQJX NOMINAL THREAD SIZE 0.164 INCHES SINGLE GROUP
ABFE HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION VIBRATION RESISTANT
AKNA INCLOSURE TYPE HERMETICALLY SEALED
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-T-27/62 GOVERNMENT SPECIFICATION
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
ADAQ BODY LENGTH 1.344 INCHES MINIMUM AND 1.406 INCHES MAXIMUM
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
ADAR BODY OUTSIDE DIAMETER 1.344 INCHES MINIMUM AND 1.406 INCHES MAXIMUM
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP

Similar Parts