Part Number
Definition:
AN ITEM GENERALLY CONSISTING OF ONE OR MORE TURNS OF WIRE OR SIMILAR CONDUCTIVE MATERIAL (IN SPECIAL CASES IT MAY BE CONSIDERED AS A PARTIAL TURN). IT IS SPECIFICALLY DESIGNED TO CONCENTRATE MAGNETIC FLUX GENERATED BY THE FLOW OF AN ELECTRIC CURRENT, TO INDUCE IN ITSELF AN ELECTROMOTIVE FORCE, AND TO ADD OR SUBTRACT INDUCTIVE REACTANCE IN A CIRCUIT. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). FOR COILS WOUND ON RESISTORS WHICH ARE DESIGNED TO BE INSERTED INTO THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC..
CAGE Information
Code | Company |
---|---|
95776 | COLTEC INDUSTRIES INC CENTRAL MOLONE |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAU | BODY HEIGHT | 1.672 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 27.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAT | BODY WIDTH | 1.609 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
ADAQ | BODY LENGTH | 1.875 INCHES NOMINAL |
ACYV | INDUCTANCE RATING | 33.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 60.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE WINDING |