CAPACITOR , FIXED , GLASS DIELECTRIC
Definition:
A CAPACITOR, WHOSE CAPACITANCE VALUE CANNOT BE ADJUSTED OR VARIED, HAVING A GLASS (SILICAS) OR GLASS LIKE SUBSTANCE (E.G., PORCELAIN, VITREOUS ENAMEL) AS THE DIELECTRIC MATERIAL. IT MAY BE A SINGLE UNIT, OR CONSIST OF TWO OR MORE FIXED UNITS WHICH CANNOT BE SEPARATED.
CAGE Information
Code | Company |
---|---|
05869 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
CAPACITORS
Inclusions:
INCLUDES INTERFERENCE FILTER CAPACITORS; CAPACITOR MOUNTING HARDWARE.
Exclusions:
EXCLUDES SEMICONDUCTOR DEVICES AND ASSOCIATED HARDWARE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE |
CQBQ | CAPACITANCE VALUE PER SECTION | 750.000 PICOFARADS SINGLE SECTION |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.1000 |
AEBT | TERMINAL DIAMETER | 0.032 INCHES NOMINAL |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-23269 SPECIFICATION |
AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | C |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
ABKW | OVERALL HEIGHT (NON-CORE) | 0.219 INCHES NOMINAL |
CWJK | CASE MATERIAL | GLASS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-23269/6 GOVERNMENT SPECIFICATION |
ABHP | OVERALL LENGTH (NON-CORE) | 0.484 INCHES NOMINAL |
CWQF | QUALITY FACTOR AT REFERENCE TEMP | 2000.0000 |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.0100 |
ADAT | BODY WIDTH | 0.281 INCHES NOMINAL |
CQLZ | TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 105.0 SINGLE SECTION |
ADAQ | BODY LENGTH | 0.484 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
ABJT | TERMINAL LENGTH | 1.125 INCHES MINIMUM |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 500000.0 MEGOHMS |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
CRTP | TOLERANCE RANGE PER SECTION | -1.00/+1.00 PERCENT SINGLE SECTION |
CRHD | TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -25.0/+25.0 SINGLE SECTION |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.400 INCHES NOMINAL |
ABMK | OVERALL WIDTH (NON-CORE) | 0.281 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.219 INCHES NOMINAL |
CQBF | INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 100000.0 MEGOHMS |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 300.0 DC SINGLE SECTION |