Part Number
Part Number:
NSN:
NIIN:
Item Name:
MOTOR , DIRECT CURRENT
Definition:
A MOTOR WHICH IS DESIGNED FOR OPERATION FROM A DIRECT CURRENT SOURCE. EXCLUDES MOTOR, ENGINE STARTER, ELECTRICAL. SEE ALSO MOTOR, CONTROL.
CAGE Information
Code | Company |
---|---|
59364 | HONEYWELL INTERNATIONAL INC. DBA HON |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
ABWV | SHAFT DIAMETER | 0.1875 INCHES NOMINAL SINGLE END |
AKCT | SHAFT ROTATION DIRECTION | CLOCKWISE SINGLE END |
AXCP | WINDING TYPE | SHUNT WOUND |
BKPQ | INCLOSURE SPECIFICATION | COMMERCIAL |
CWGL | CURRENT RATING IN AMPS | 0.300 SINGLE INPUT |
CWHZ | SHAFT END CHARACTERISTIC | A24 SINGLE STYLE SINGLE END |
CWCS | LENGTH OF SHAFT FROM HOUSING | 2.438 INCHES SINGLE END |
AAJV | OVERALL WIDTH | 2.250 INCHES |
AAJT | OVERALL HEIGHT | 2.250 INCHES |
AKPS | DUTY CYCLE | CONTINUOUS |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 24.0 LINE TO NEUTRAL SINGLE INPUT |
ANPZ | INCLOSURE FEATURE | EXPLOSION PROOF |
AAJU | OVERALL LENGTH | 4.344 INCHES |
CNXS | POWER RATING | 0.0160 HORSEPOWER OUTPUT |
BKPB | CURRENT RATING METHOD | LOAD |
CWFY | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.073 INCHES |
CWDT | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.812 INCHES |
CWFX | ROTOR SPEED RATING IN RPM | 8650.0 SINGLE FULL LOAD |