Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
COMPRESSOR UNIT , REFRIGERATION

Definition:

AN ITEM CONSISTING OF A REFRIGERATION COMPRESSOR AND PRIME MOVER, IT MAY BE OPEN OR ENCLOSED IN A HERMETICALLY SEALED HOUSING, HAVING INLET AND OUTLET CONNECTIONS AND FACILITIES FOR MOUNTING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
KAM2-0050-1AA200 14569 F 3 2 5 9Z
KAM2-0050-IAA-200 14569 F 3 9 E CX

CAGE Information

Code Company
14569 COPELAND CORP

Federal Supply Class

Title

REFRIGERATION AND AIR CONDITIONI

Inclusions:

INCLUDES HEAT EXCHANGER EQUIPMENT; REFRIGERANT STRAINERS; REFRIGERATION COMPRESSORS; AIR CONDITIONING AND REFRIGERATION SERVICING EQUIPMENT, SUCH AS CHARGING AND TESTING MANIFOLDS, LINES AND UNITS; OPERATING COMPONENTS OF REFRIGERATION AND AIR CONDITIONING EQUIPMENT, PLANTS, AND SYSTEMS CLASSIFIED IN CLASSES 4110 AND 4120.

Exclusions:

EXCLUDES REFRIGERATION AND AIR CONDITIONING PLANTS (SEE CLASSES 4110 AND 4120): COLLECTIONS OF REFRIGERATION COMPONENTS "PACKAGED" AS A UNIT INCLUDING A REFRIGERATION COMPRESSOR, CONDENSER, EVAPORATOR, ETC., SPECIFICALLY DESIGNED AND TAILORED FOR APPLICATIONS SUCH AS WALK-IN TYPE REFRIGERATORS. INDIVIDUAL COMPONENTS OF THE "PACKAGED" UNIT WILL BE CLASSIFIED IN CLASS 4130, OR AS OTHERWISE SPECIFICALLY PRESCRIBED BY THE INDEXES AND STRUCTURE OF THE FSC. THE COMPLETE "PACKAGE" UNIT WILL BE CLASSIFIED IN CLASS 4110.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
FREQ FREQUENCY IN HERTZ 60.0
AAYS COMPRESSOR SPEED AT RATED CAPACITY IN RPM 1725.0
AAXS PRIME MOVER COOLING MEDIUM AIR
CSFH TEMP RATING PER FUNCTION NOT RATED
CSBH VOLTAGE IN VOLTS AND CURRENT TYPE 115.0 AC
AAXP COOLING SYSTEM DESIGN SINGLE
AAXM DISCHARGE PRESSURE NOT RATED
AKDJ PRIME MOVER TYPE ELECTRIC MOTOR
AAYE REFRIGERATION FLOW RATE IN TONS PER HOUR NOT RATED
AAYA CYLINDER ARRANGEMENT STYLE VERTICAL DESIGN
AAXJ DUTY CYCLE IN PERCENT NOT RATED
AAXW BRAKE HORSEPOWER REQUIRED 0.500
AAXL DISCHARGE FLOW RATE 2.816 CUBIC FEET PER MINUTE
AAYT INTAKE CONNECTION QUANTITY 1
AAXZ CYLINDER QUANTITY 2
AAYD STAGE QUANTITY 1
AAYW DISCHARGE CONNECTION TYPE FLARED TUBE
AAXR COMPRESSOR COOLING MEDIUM AIR
AAYU INTAKE CONNECTION TYPE FLARED TUBE
AAYV DISCHARGE CONNECTION QUANTITY 1
AAXX MOUNTING TYPE BASE
AAXK GAS FOR WHICH DESIGNED REFRIGERANT R-12
CQJY CURRENT TYPE AND RATING IN AMPS NOT RATED
AAXY RECIPROCATING COMPRESSOR DESIGN SINGLE ACTING
FAAZ PHASE SINGLE

Similar Parts

KAM2-0050-1AA200 , KAM200501AA200 , 4130-01-123-2825 , 4130011232825 , 011232825 , KAM2-0050-1AA200 , KAM2-0050-IAA-200 ,