National Stock Number (NSN) Output Data
Definition:
AN ITEM CONSISTING OF A REFRIGERATION COMPRESSOR AND PRIME MOVER, IT MAY BE OPEN OR ENCLOSED IN A HERMETICALLY SEALED HOUSING, HAVING INLET AND OUTLET CONNECTIONS AND FACILITIES FOR MOUNTING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
KAM2-0050-1AA200 | 14569 | F | 3 | 2 | 5 | 9Z | ||
KAM2-0050-IAA-200 | 14569 | F | 3 | 9 | E | CX |
CAGE Information
Code | Company |
---|---|
14569 | COPELAND CORP |
Federal Supply Class
Title
REFRIGERATION AND AIR CONDITIONI
Inclusions:
INCLUDES HEAT EXCHANGER EQUIPMENT; REFRIGERANT STRAINERS; REFRIGERATION COMPRESSORS; AIR CONDITIONING AND REFRIGERATION SERVICING EQUIPMENT, SUCH AS CHARGING AND TESTING MANIFOLDS, LINES AND UNITS; OPERATING COMPONENTS OF REFRIGERATION AND AIR CONDITIONING EQUIPMENT, PLANTS, AND SYSTEMS CLASSIFIED IN CLASSES 4110 AND 4120.
Exclusions:
EXCLUDES REFRIGERATION AND AIR CONDITIONING PLANTS (SEE CLASSES 4110 AND 4120): COLLECTIONS OF REFRIGERATION COMPONENTS "PACKAGED" AS A UNIT INCLUDING A REFRIGERATION COMPRESSOR, CONDENSER, EVAPORATOR, ETC., SPECIFICALLY DESIGNED AND TAILORED FOR APPLICATIONS SUCH AS WALK-IN TYPE REFRIGERATORS. INDIVIDUAL COMPONENTS OF THE "PACKAGED" UNIT WILL BE CLASSIFIED IN CLASS 4130, OR AS OTHERWISE SPECIFICALLY PRESCRIBED BY THE INDEXES AND STRUCTURE OF THE FSC. THE COMPLETE "PACKAGE" UNIT WILL BE CLASSIFIED IN CLASS 4110.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FREQ | FREQUENCY IN HERTZ | 60.0 |
AAYS | COMPRESSOR SPEED AT RATED CAPACITY IN RPM | 1725.0 |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
CSFH | TEMP RATING PER FUNCTION | NOT RATED |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
AAXP | COOLING SYSTEM DESIGN | SINGLE |
AAXM | DISCHARGE PRESSURE | NOT RATED |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
AAYE | REFRIGERATION FLOW RATE IN TONS PER HOUR | NOT RATED |
AAYA | CYLINDER ARRANGEMENT STYLE | VERTICAL DESIGN |
AAXJ | DUTY CYCLE IN PERCENT | NOT RATED |
AAXW | BRAKE HORSEPOWER REQUIRED | 0.500 |
AAXL | DISCHARGE FLOW RATE | 2.816 CUBIC FEET PER MINUTE |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AAXZ | CYLINDER QUANTITY | 2 |
AAYD | STAGE QUANTITY | 1 |
AAYW | DISCHARGE CONNECTION TYPE | FLARED TUBE |
AAXR | COMPRESSOR COOLING MEDIUM | AIR |
AAYU | INTAKE CONNECTION TYPE | FLARED TUBE |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
AAXX | MOUNTING TYPE | BASE |
AAXK | GAS FOR WHICH DESIGNED | REFRIGERANT R-12 |
CQJY | CURRENT TYPE AND RATING IN AMPS | NOT RATED |
AAXY | RECIPROCATING COMPRESSOR DESIGN | SINGLE ACTING |
FAAZ | PHASE | SINGLE |