Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
05869 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC INDUCTIVE LOAD AND 3.0 AMPERES DC INDUCTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 14 WIRE HOOK ALL FUNCTIONS |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-5757/15 GOVERNMENT SPECIFICATION |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.687 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
APCN | COIL QUANTITY | 1 |
CRXH | TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE TIME |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 1.130 INCHES MAXIMUM |
CBME | CUBIC MEASURE | 3.783 CUBIC INCHES |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | AIR |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
ABHP | OVERALL LENGTH | 1.531 INCHES MAXIMUM |
APNP | DUTY TYPE | CONTINUOUS |
APNA | WINDING DC RESISTANCE RATING | 1.4 KILOHMS NOMINAL SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 800.0 MILLIAMPERES AC LAMP LOAD AND 800.0 MILLIAMPERES DC LAMP LOAD |
ABKW | OVERALL HEIGHT | 2.187 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-5757 SPECIFICATION |
ADTV | CASE MATERIAL | METAL |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |