Part Number
Definition:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
80020 | NAVAL AIR WARFARE CENTER AIRCRAFT DI |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.062 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 1.75 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY INPUT AND 2.25 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY INPUT |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 3.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AARD | DUMMY TERMINAL QUANTITY (NON-CORE) | 1 |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 130.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT |
TTQY | TERMINAL TYPE AND QUANTITY | 3 THREADED STUD |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CRMJ | WINDING POWER RATING | 230.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
AGAV | END ITEM IDENTIFICATION | STREAM (STD.TENSIONED REPLENISHMENT AT SEA METHOD); AIR TRAFFIC CONTROL CENTRAL AN/TSW-7C; TELETYPE, MODEL 28; HELICOPTER LANDING SYSTEM, LAMPS MK III; KIDD CLASS DDG; TICONDEROGA CG (47); ARLEIGH BURKE DDG; SPRUANCE DD (963); NIMITZ CVN |
AHHX | SCALE DIRECTION AND RANGE (NON-CORE) | +0.0/+120.0 CLOCKWISE |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
AEHZ | MAXIMUM OPERATING TEMP | 90.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | OPEN |
ADAR | BODY OUTSIDE DIAMETER | 2.812 INCHES NOMINAL |