National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
PUMP UNIT , CENTRIFUGAL
Definition:
AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED CENTRIFUGAL PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
RY144686 | 93232 | C | C | 1 | 6 | ZZ | AC | |
RY144686SH2 | 93232 | C | 3 | 1 | 1 | HD | ||
RY144686 F93232 | 03950 | A | C | 1 | 5 | ZZ | AC |
CAGE Information
Code | Company |
---|---|
03950 | NAVAL INVENTORY CONTROL POINT MECHAN |
93232 | CURTISS-WRIGHT ELECTRO-MECHANICAL CO |
Federal Supply Class
Title
POWER AND HAND PUMPS
Inclusions:
Exclusions:
EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHYW | DISCHARGE PRESSURE | 80.0 POUNDS PER SQUARE INCH GAGE |
AHYW | DISCHARGE PRESSURE | 80.0 POUNDS PER SQUARE INCH GAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 |
AENK | COOLING METHOD | SELF VENTILATED |
AHZF | CENTRIFUGAL PUMP IMPELLER QUANTITY | 2 |
ADZC | ENVIRONMENTAL PROTECTION | DRIPPROOF |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
AENC | PUMP QUANTITY | 1 |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY PRIME MOVER TYPE REQUIREMENT,ELECTRIC MOTOR MFR GENERAL ELECTRIC CO LOW VOLTAGE SWITCHGEAR PRODUCTS DEPT PART NO. 5K6238XH301A |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
AHZG | CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
FAAZ | PHASE | THREE |
AHYX | TOTAL HEAD | 185.000 FEET |
AMPS | CURRENT RATING IN AMPS | 39.5 |
AHYV | MAXIMUM DISCHARGE FLOW RATE | 325.0 GALLONS PER MINUTE |
AAYU | INTAKE CONNECTION TYPE | ROUND FLANGE |
AHZA | PUMPING ELEMENT OPERATING POSITION | VERTICAL |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AAXH | PRIME MOVER QUANTITY | 1 |
AAYW | DISCHARGE CONNECTION TYPE | ROUND FLANGE |
ACKL | MEDIA FOR WHICH DESIGNED | WATER, FRESH |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
AHYZ | OPERATING SPEED AT RATED CAPACITY | 1800.0 REVOLUTIONS PER MINUTE |
AAXX | MOUNTING TYPE | BASE |
AAYD | STAGE QUANTITY | 2 |
ACDC | CURRENT TYPE | AC |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED |
AHZE | CENTRIFUGAL PUMP DESIGN | RADIAL FLOW |
ELEC | VOLTAGE IN VOLTS | 440.0 |