National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
PUMP UNIT , CENTRIFUGAL
Definition:
AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED CENTRIFUGAL PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
16N-0-98-014 | 10941 | A | 3 | 2 | E | AX | ||
D16N-0-98-014 | 10941 | A | D | 9 | A | AX |
CAGE Information
Code | Company |
---|---|
10941 | CARVER PUMP COMPANY INC |
Federal Supply Class
Title
POWER AND HAND PUMPS
Inclusions:
Exclusions:
EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AMPS | CURRENT RATING IN AMPS | 67.7 |
FREQ | FREQUENCY IN HERTZ | 60.0 |
AHZF | CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
AHZV | SUBMERSIBILITY (NON-CORE) | NONSUBMERSIBLE |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
ACKL | MEDIA FOR WHICH DESIGNED | BRINE |
AENC | PUMP QUANTITY | 1 |
FEAT | SPECIAL FEATURES | INTAKE AND DISCHARGE FLANGE CONNECTIONS ARE PER MIL-F-20042G AMEND 7,0.688 IN.DIA THRU. 1.250 IN.DIA SPOTFACED ON OPP SIDE,12 HOLES ON 10.0DEG |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
AHZG | CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
FAAZ | PHASE | THREE |
AHZA | PUMPING ELEMENT OPERATING POSITION | HORIZONTAL |
CSYL | PRIME MOVER POWER RATING | 40.000 HORSEPOWER |
AHYV | MAXIMUM DISCHARGE FLOW RATE | 1080.0 GALLONS PER MINUTE |
AAYU | INTAKE CONNECTION TYPE | ROUND FLANGE |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AENK | COOLING METHOD | AIR TO AIR COOLED |
AAXH | PRIME MOVER QUANTITY | 1 |
AAYW | DISCHARGE CONNECTION TYPE | ROUND FLANGE |
AAYD | STAGE QUANTITY | 1 |
AAXX | MOUNTING TYPE | FRAME |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
AHYW | DISCHARGE PRESSURE | 955.0 POUNDS PER SQUARE INCH GAGE |
AHYZ | OPERATING SPEED AT RATED CAPACITY | 1800.0 REVOLUTIONS PER MINUTE |
AHYX | TOTAL HEAD | 80.000 FEET |
ACDC | CURRENT TYPE | AC |
AHZE | CENTRIFUGAL PUMP DESIGN | MIXED FLOW |
ELEC | VOLTAGE IN VOLTS | 440.0 |