TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
79986 BATTELLE MEMORIAL INSTITUTE

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ZZZK SPECIFICATION/STANDARD DATA 79986-4404184001 MANUFACTURERS SPECIFICATION CONTROL
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 7.000 POUNDS
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
ABKW OVERALL HEIGHT 2.850 INCHES MAXIMUM
AKNA INCLOSURE TYPE FULLY INCLOSED
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 22.60 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
CWJS WINDING OPERATING VOLTAGE 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CQLC WINDING TAP LOCATION (NON-CORE) NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY
CRBZ WINDING OPERATING CURRENT 0.2 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
ACZF MAXIMUM TRANSFORMER POWER RATING 1010.0 VOLT-AMPERE SINGLE COMPONENT
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ABMK OVERALL WIDTH 2.700 INCHES MAXIMUM
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
AKPV MOUNTING FACILITY QUANTITY 6 SINGLE GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 11 WIRE LEAD
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENT
ACZX WINDING SHIELDING METHOD CORE GROUNDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
ABHP OVERALL LENGTH 5.810 INCHES MAXIMUM
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 34.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
AARD DUMMY TERMINAL QUANTITY (NON-CORE) 4
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 2ND SECONDARY
CRBZ WINDING OPERATING CURRENT 9.3 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
AEHZ MAXIMUM OPERATING TEMP 155.0 DEG CELSIUS