National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
HEATER , SPACE
Definition:
A DEVICE DESIGNED TO BURN VARIOUS TYPES OF FUEL WITHIN AN INCLOSURE WHICH PROTECTS AND CONFINES THE FIRE. IT IS USED FOR THE PURPOSE OF RAISING THE TEMPERATURE OF THE AIR IN ITS IMMEDIATE VICINITY. THE INCLOSURE MAY BE VENTED. EXCLUDES HEATER, DUCT TYPE, PORTABLE AND HEATER, SPACE, ELECTRIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
MPEG12A | 06178 | A | 3 | 2 | 5 | ZZ | ||
PEG-12A | 06178 | A | 5 | 2 | 4 | SB |
CAGE Information
Code | Company |
---|---|
06178 | PUREGAS LLC |
Federal Supply Class
Title
SPACE AND WATER HEATING EQUIPMEN
Inclusions:
INCLUDES BOILERS, 15 POUNDS WSP AND UNDER (FOR BOILERS OVER 15 POUNDS WSP, SEE FSC 4410); DOMESTIC WATER STORAGE TANKS THROUGH 100 GALLON CAPACITY; FIREPLACE HEATERS; FURNACES; SPACE HEATERS; HEATING RADIATORS; IMMERSION HEATERS; WATER HEATERS, THROUGH 100 GALLON RECOVERY CAPACITY (FOR HEATERS OVER 100 GALLONS RECOVERY CAPACITY, SEE FSC 4410).
Exclusions:
EXCLUDES VEHICLE HEATERS; (FSC 2540); AIRCRAFT HEATERS (FSC 1660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BDXJ | HEATING ELEMENT TYPE | BURNER |
ABGL | WIDTH | 23.500 INCHES NOMINAL |
AAXX | MOUNTING TYPE | ANY ACCEPTABLE |
HGTH | HEIGHT | 21.250 INCHES NOMINAL |
CSGC | FUEL FEED METHOD | ANY ACCEPTABLE |
ALYC | OPERATING CONTROL TYPE | ANY ACCEPTABLE |
CQXD | HEAT DELIVERY RATE | 55000.0 BRITISH THERMAL UNIT |
ABAM | HEAT MEDIUM TYPE | AIR |
BLJC | IGNITION METHOD | ELECTRODE |
FUEL | FUEL TYPE | PROPANE |