National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
HEATER , CONVECTION , STEAM-HOT WATE
Definition:
A HEAT TRANSFERRING UNIT, INCLOSED IN A CABINET, DESIGNED TO WARM A STREAM OF AIR BY CONVECTION AS IT CIRCULATES OVER THE HEATING ELEMENTS RATHER THAN BY DIRECT RADIATION. EXCLUDES RADIATOR, HEATING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
MILH3117 | 81349 | M | 4 | 1 | 3 | AX | ||
S3802-921624-2NM | 80064 | A | 5 | 9 | 5 | AX | ||
S3802-921624-2NM | 53711 | A | 3 | 2 | 5 | AX |
CAGE Information
Code | Company |
---|---|
53711 | NAVAL SEA SYSTEMS COMMAND |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
80064 | NAVAL SHIP SYSTEMS COMMAND |
Federal Supply Class
Title
SPACE AND WATER HEATING EQUIPMEN
Inclusions:
INCLUDES BOILERS, 15 POUNDS WSP AND UNDER (FOR BOILERS OVER 15 POUNDS WSP, SEE FSC 4410); DOMESTIC WATER STORAGE TANKS THROUGH 100 GALLON CAPACITY; FIREPLACE HEATERS; FURNACES; SPACE HEATERS; HEATING RADIATORS; IMMERSION HEATERS; WATER HEATERS, THROUGH 100 GALLON RECOVERY CAPACITY (FOR HEATERS OVER 100 GALLONS RECOVERY CAPACITY, SEE FSC 4410).
Exclusions:
EXCLUDES VEHICLE HEATERS; (FSC 2540); AIRCRAFT HEATERS (FSC 1660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABAW | HEAT OUTLET QUANTITY | 1 |
ABAW | HEAT OUTLET QUANTITY | 1 |
AAXX | MOUNTING TYPE | WALL RECESSED, ROOM INTERIOR |
ABGL | WIDTH | 10.500 INCHES NOMINAL |
BDXJ | HEATING ELEMENT TYPE | HOT WATER COIL AND STEAM COIL |
ABAY | HEAT DISCHARGE OUTLET TYPE | STATIONARY |
ABAZ | HEAT DIRECTING DEVICE | FIXED LOUVER |
CQXD | HEAT DELIVERY RATE | 1675.0 BRITISH THERMAL UNIT |
ABAN | MAXIMUM PRESSURE LIMIT | 35.0 POUNDS PER SQUARE INCH GAGE |
CQSJ | INCLOSURE MATERIAL | ALUMINUM |
ALYC | OPERATING CONTROL TYPE | ANY ACCEPTABLE |
ABAX | HEAT DELIVERY DIRECTION | VERTICAL |
FEAT | SPECIAL FEATURES | MAGNETIC PERMEABILITY SHALL BE LESS THAN 1.2 BEFORE FABRICATION AND NOT GREATER THAN 2.0 AFTER FABRICATION AS MEASURED IN A 200 OERSTED FIELD |
HGTH | HEIGHT | 20.000 INCHES NOMINAL |
AEJZ | DEPTH | 4.000 INCHES NOMINAL |
ABAM | HEAT MEDIUM TYPE | HOT WATER |