Part Number
Part Number:
NSN:
NIIN:
Item Name:
MOTOR , CONTROL
Definition:
A MOTOR WHICH IS DESIGNED TO BE OPERATED FROM TWO INDEPENDENT VOLTAGE SOURCES, IN SUCH A WAY THAT VARIATIONS IN ONE VOLTAGE SOURCE WILL DETERMINE THE DIRECTION AND SPEED OF THE MOTOR. IN THE ALTERNATING CURRENT TYPE THE VOLTAGES ARE USUALLY APPLIED TO A SPLIT-PHASE STATOR, WHEREAS IN THE DIRECT CURRENT TYPE, ONE VOLTAGE IS APPLIED TO THE STATOR AND THE OTHER TO THE ARMATURE. LOW INERTIA AND RAPID REVERSIBILITY ARE INHERENT CHARACTERISTICS OF THIS TYPE OF MOTOR. SEE ALSO SERVOMOTOR, AUTOMATIC PILOT.
CAGE Information
Code | Company |
---|---|
94580 | HONEYWELL INTERNATIONAL INC DBA HONE |
Federal Supply Class
Title
MOTORS, ELECTRICAL
Inclusions:
Exclusions:
EXCLUDES STARTING MOTORS FOR ENGINES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWCS | LENGTH OF SHAFT FROM HOUSING | 0.094 INCHES SINGLE END |
ACDC | CURRENT TYPE | AC INPUT |
BFMK | CONTROL FIELD IMPEDANCE RATING IN OHMS | 215.0 |
AAJT | OVERALL HEIGHT | 1.062 INCHES |
CWFX | ROTOR SPEED RATING IN RPM | 10800.0 SINGLE NO LOAD |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 115.0 LINE TO NEUTRAL SINGLE INPUT |
ANPZ | INCLOSURE FEATURE | TOTALLY INCLOSED |
CBBL | FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
AAJU | OVERALL LENGTH | 0.844 INCHES |
BKPB | CURRENT RATING METHOD | NO LOAD |
BFMJ | CONTROL FIELD CURRENT RATING IN AMPS | 0.120 |
AJLA | TEETH QUANTITY | 12 SINGLE END |
CWHZ | SHAFT END CHARACTERISTIC | A23 SINGLE STYLE SINGLE END |
BKPQ | INCLOSURE SPECIFICATION | COMMERCIAL |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 CLAMP COLLAR |
BKPH | TORQUE RATING AND TYPE | 0.2 INCH-OUNCES STALLED |
AAJV | OVERALL WIDTH | 1.062 INCHES |
FREQ | FREQUENCY IN HERTZ | 400.0 INPUT |
FAAZ | PHASE | SINGLE INPUT |
AXGY | MOUNTING METHOD | CLAMP RING |
BKPS | CONTROL FIELD VOLTAGE TYPE AND RATING IN VOLTS | 26.0 AC |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 20000.0 FEET |
CWGL | CURRENT RATING IN AMPS | 0.040 SINGLE INPUT |
ABWV | SHAFT DIAMETER | 0.1250 INCHES NOMINAL SINGLE END |
CWDY | TEMP RATING | -54.0 OPERATING DEG CELSIUS AND 149.0 OPERATING DEG CELSIUS |
BFML | CONTROL FIELD WINDING TYPE | SINGLE WINDING |
BFMF | COOLING METHOD | NONVENTILATED |