Part Number
Part Number:
NSN:
NIIN:
Item Name:
REACTOR
Definition:
A COIL OR COILS USUALLY CONSTRUCTED WITH CORES HAVING LOW MAGNETIC RELUCTANCE, WHOSE PRIMARY PURPOSE IS TO FURNISH AN INDUCTIVE IMPEDANCE IN POWER OR AUDIO FREQUENCY CIRCUIT RANGING FROM ZERO TO 20 KILOHERTZ (KILOCYCLES). INCLUDES AUDIO FREQUENCY AND POWER FILTER CHOKES, AUDIO REACTORS AND SWINGING CHOKES. DOES NOT INCLUDE TRANSFORMERS OR COILS USED ABOVE AUDIO FREQUENCY RANGE. EXCLUDES SATURABLE REACTOR. FOR REACTORS WITH AIR CORES, SEE COIL (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
82577 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CBME | CUBIC MEASURE (NON-CORE) | 1.3 CUBIC INCHES |
ACYV | INDUCTANCE RATING | 19.00 MICROHENRIES MINIMUM SINGLE COMPONENT 1ST WINDING AND 22.00 MICROHENRIES MAXIMUM SINGLE COMPONENT 1ST WINDING |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL WINDING |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
CRGS | DC RESISTANCE RATING IN OHMS | 0.022 SINGLE COMPONENT 1ST WINDING |
AGAV | END ITEM IDENTIFICATION | 1440-01-215-4868,ARMAMENT SUBSYSTEM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.850 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
AKDX | WINDING QUANTITY | 2 SINGLE COMPONENT |
ADAT | BODY WIDTH | 1.130 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 15.75 KILOHERTZ NOMINAL SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT ALL WINDING |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 300.0 GRAMS |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ADAQ | BODY LENGTH | 1.130 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
ACYF | INDUCTANCE TYPE | FIXED |
AEHZ | MAXIMUM OPERATING TEMP | 60.0 DEG CELSIUS |
ACYV | INDUCTANCE RATING | 6.65 MICROHENRIES MINIMUM SINGLE COMPONENT 2ND WINDING AND 66.00 MICROHENRIES MAXIMUM SINGLE COMPONENT 2ND WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.462 SINGLE COMPONENT 2ND WINDING |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE LEAD |
ADAU | BODY HEIGHT | 0.740 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.850 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 2ND WINDING |