Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
89305 | SIMMONDS PRECISION PRODUCTS INC. DBA |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWJS | WINDING OPERATING VOLTAGE | 1.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 34.10 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 44.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 50.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 34.10 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 44.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 50.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
ADAT | BODY WIDTH | 1.440 INCHES NOMINAL |
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/O CENTER TAP SINGLE COMPONENT 1ST SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAQ | BODY LENGTH | 0.680 INCHES NOMINAL |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPEN |
TTQY | TERMINAL TYPE AND QUANTITY | 10 WIRE LEAD |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 6.90 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY AND 19.90 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |