Part Number
Part Number:
NSN:
NIIN:
Item Name:
INSULATION SLEEVING , ELECTRICAL , S
Definition:
A RIGID OR FLEXIBLE TUBING HAVING OTHER THAN UNIFORM FABRICATED SHAPES OR FORMS. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS OR BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE ITEMS. EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; AND INSULATION SLEEVING, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
20999 | 3M CO ADMININISTRATIVE ELECTRONIC & |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFZU | MAIN BODY INSIDE DIAMETER | 0.620 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAH | MAIN BODY OVERALL LENGTH | 3.250 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
HUES | COLOR | BLACK |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH/ |
ADZC | ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND SOLVENT RESISTANT AND FLAME RESISTANT AND CORROSION RESISTANT AND WATER RESISTANT |
AGAB | MAIN BODY WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
AGAB | MAIN BODY WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
STYL | STYLE DESIGNATOR | TRANSITION-45 DEGREES |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
MATL | MATERIAL | PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
AGAG | DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 1.250 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAA | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 2.000 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.420 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 30.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.800 INCHES MINIMUM AS SUPPLIED |
AGAC | FIRST BRANCH WALL THICKNESS | 0.070 INCHES MAXIMUM AS SUPPLIED |
AGAC | FIRST BRANCH WALL THICKNESS | 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
FLEX | FLEXIBILITY | SEMIRIGID |
AFZU | MAIN BODY INSIDE DIAMETER | 1.200 INCHES MINIMUM AS SUPPLIED |
ABJH | TEMP RATING | -55.0 DEG CELSIUS |