Definition:
A TEST INSTRUMENT WHICH IS DESIGNED TO GIVE VISUAL INDICATIONS ON A CATHODE RAY TUBE OF INSTANTANEOUS VALUES AND VARIATIONS IN ELECTRICAL VOLTAGE. IT CAN ALSO BE USED TO INDICATE ANY QUANTITY WHICH CAN BE CONVERTED INTO TERMS OF ELECTRICAL POTENTIAL. IT MAY INCLUDE AN INTEGRAL PULSE GENERATOR, THE OUTPUT OF WHICH CAN BE USED TO TRIGGER AN EXTERNAL COMPONENT; BE TRIGGERED BY PULSES FROM AN EXTERNAL SOURCE, OR IT MAY UTILIZE A SPECIAL TYPE OF MULTIGUN CATHODE RAY TUBE AND CIRCUITRY WHICH PERMITS A TRACE(S) TO BE SUSTAINED AND DISPLAYED INDEFINITELY, AND THE TRACE(S) MAY BE ERASED WHEN DESIRED. FOR ITEMS WHICH ARE NOT SEPARABLE AND OPERABLE WHEN DETACHED FROM EQUIPMENT OF WHICH THEY ARE A PART (BUILT INTO OPERATIONAL EQUIPMENT), SEE INDICATOR (2) (AS MODIFIED); MONITOR (AS MODIFIED); AND RECORDER (AS MODIFIED). SEE ALSO OSCILLOGRAPH.
CAGE Information
Code | Company |
---|---|
80009 | TEKTRONIX INC. DBA TEKTRONIX |
Federal Supply Class
Title
ELECTRICAL AND ELECTRONIC PROPER
Inclusions:
INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.
Exclusions:
EXCLUDES RADIAC EQUIPMENT
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BHFT | CAMERA RECORDING DEVICE ACCOMMODATION | NOT PROVIDED |
ACZB | FREQUENCY RATING | 48.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM |
BGQM | GENERATOR DRIVEN FEATURE | NOT INCLUDED |
BGQN | SWEEP CIRCUIT TYPE | HORIZONTAL AND VERTICAL |
BHFB | CALIBRATING PEAK TO PEAK AMPLITUDE | 0.3 VOLTS NOMINAL |
AMSE | VOLTAGE RATING | 12.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM |
BGQL | SWEEP CIRCUITS | INCLUDED |
BHFH | TRACE STORAGE TUBE | NOT INCLUDED |
BHDL | PLATE DIRECT CONNECTION DEFLECTION SENSITIVITY PROVISION | NOT PROVIDED |
ATES | BEAM QUANTITY | 1 |
BHFF | CALIBRATED SCREEN SCALE | INCLUDED |
AWEC | GRADUATION INTERVAL | GRADUATED IN 0.2 CM INCREMENTS |
BGQK | SCREEN SIZE | 8 BY 10 CENTIMETERS |
AKYD | ACCESSORY COMPONENTS AND QUANTITY | 6 FT PROBES 2,BLUE CRT LIGHT FILTER 1,CLEAR CRT LIGHT FILTER 1,GROUN D POST 1 |
BHDZ | AMPLITUDE CALIBRATING VOLTAGE WAVEFORM | ANY ACCEPTABLE |
AXGY | MOUNTING METHOD | TABLE |
BHDH | INPUT INTENSITY MODULATION FEATURE | NOT PROVIDED |
BHDD | AMPLIFIER DEFLECTION SENSITIVITY PROVISION | NOT PROVIDED |
ACDC | CURRENT TYPE | AC AND DC |
BHDT | AMPLIFIER INPUT IMPEDANCE RATING PROVISION | NOT PROVIDED |
BHDP | FREQUENCY RESPONSE RATING | NOT PROVIDED |
FAAZ | PHASE | SINGLE |