Part Number
Definition:
A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BFMF | COOLING METHOD | SELF-COOLED |
BFMF | COOLING METHOD | SELF-COOLED |
ABHP | OVERALL LENGTH | 6.500 INCHES MAXIMUM |
AJDB | POWER RATING | 168.000 KILOWATTS PEAK AND 178.000 WATTS AVERAGE |
AKSA | WAVEGUIDE FLANGE DESIGNATION | UG1725/U |
ARNH | OPERATING POSITION | HORIZONTAL |
STYL | STYLE DESIGNATOR | WAVEGUIDE MOUNTED |
ABPM | BODY DIAMETER | 5.250 NOMINAL CENTIMETERS |
FTLD | FUNCTIONAL DESCRIPTION | DUMMY LOAD,ELECTRICAL-S-BAND,MEDIUM POWER |
AKNK | VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | +2.700/+2.900 GIGAHERTZ |
AKRZ | TERMINATION TYPE | WAVEGUIDE FLANGE |
ADAV | OVERALL DIAMETER | 5.250 INCHES MAXIMUM |
ZZZV | FSC APPLICATION DATA | MICROWAVE EQUIPMENT |
TEST | TEST DATA DOCUMENT | 49956-480393 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
AWNC | INTERNAL OPERATING PRESSURE | 18.0 POUNDS PER SQUARE INCH GAGE |
AFGQ | FREQUENCY RANGE RATING | +2.700/+2.900 GIGAHERTZ |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | -18.0 AND 60.0 |