Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
VALVE , LINEAR , DIRECTIONAL CONTROL

Definition:

A MANUALLY OR POWER OPERATED VALVE HAVING THREE OR MORE PORTS. THE DIRECTION OF THE FLOW THROUGH THE VARIOUS PORTS IS CONTROLLED BY EITHER ONE OR MORE RECIPROCATING SLIDE(S) OR SPOOL(S) WITH RECESS AREAS WHICH MATE WITH PORTS IN AN INTEGRAL OR REPLACEABLE PORTED SLEEVE, OR ONE OR MORE POPPET(S). IT IS DESIGNED TO CHANGE THE DIRECTION OF FLUID FLOW FROM ONE VALVE PORT TO ANOTHER. AN OFF (NO FLOW) POSITION IS NOT A FLOW PATTERN. THE VALVE IS DESIGNED TO ACTUATE VARIOUS COMPONENTS OF A FLUID SYSTEM. A POWER OPERATED VALVE MAY HAVE A MANUAL OVERRIDE. FOR ITEMS WHICH STOP, START, OR CHANGE THE FLOW OF FLUID, SEE: VALVE, SOLENOID. EXCLUDES VALVE, PLUG. SEE ALSO SERVOVALVE, HYDRAULIC; BODY SECTION, WORKING, LINEAR DIRECTIONAL CONTROL VALVE; AND VALVE ASSEMBLY.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
D1VW20BJ50 83259 A C 1 6 ZZ AC
DIVW20BNJCF72 09990 A 3 2 6 ZZ
QJ-005C-10B-DC24 09058 A 5 9 E AX
QJ-005C-10B-DC2 24785 H C 1 6 ZZ AC
D1VW20BJ50 09990 A 5 9 6 AX
D1VW20BJF 09990 A C 1 6 ZZ AC

CAGE Information

Code Company
09058 BNS HOLDING INC. DBA BNS CO DIV PREC
83259 PARKER-HANNIFIN CORPORATION DBA COMP
09990 PARKER-HANNIFIN CORPORATION DBA HYDR
24785 VICKERS INC

Federal Supply Class

Title

VALVES, POWERED

Inclusions:

INCLUDES ELECTRIC MOTOR OPERATED VALVES; HYDRAULIC OPERATED VALVES; SOLENOID OPERATED VALVES.

Exclusions:

EXCLUDES ENGINE INTAKE AND EXHAUST VALVES (FSC 2990, 2815); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
FEAT SPECIAL FEATURES SINGLE SOLENOID;CONDUIT BOX CONNECTION
AQLR VALVE OPERATION METHOD SOLENOID
CYGZ SPOOL POSITION QUANTITY 2
CBBL FEATURES PROVIDED SPRING OFFSET
CQCJ MAXIMUM OPERATING PRESSURE AND MEDIA FOR WHICH DESIGNED 3000.0 POUNDS PER SQUARE INCH HYDRAULIC FLUID, PETROLEUM BASE
CRWH MAXIMUM OPERATING TEMP AND MEDIA FOR WHICH DESIGNED 100.0 DEG FAHRENHEIT HYDRAULIC FLUID, PETROLEUM BASE
CYHB SPOOL QUANTITY 1
ADQZ END CONNECTION QUANTITY 4
CYGY FLOW PATTERN QUANTITY 4
AMPS CURRENT RATING IN AMPS 1.3
CSBH VOLTAGE IN VOLTS AND CURRENT TYPE 24.0 DC

Similar Parts

QJ-005C-10B-DC24 , QJ005C10BDC24 , 4810-01-225-6980 , 4810012256980 , 012256980 , D1VW20BJ50 , DIVW20BNJCF72 , QJ-005C-10B-DC24 , QJ-005C-10B-DC2 , D1VW20BJ50 , D1VW20BJF ,