National Stock Number (NSN) Output Data
Definition:
A VALVE DESIGNED TO AUTOMATICALLY MAINTAIN WITHIN CLOSE LIMITS A PREDETERMINED OUTLET PRESSURE WHICH MAY BE ADJUSTABLE WITHIN A SPECIFIED RANGE REGARDLESS OF THE HIGHER FLUCTUATING OR CONSTANT INLET PRESSURE. IT IS DESIGNED FOR USE WITH COMPRESSED GAS(ES) AND VARIOUS LIQUIDS AND MAY INCLUDE GAUGES. IT MAY BE INLINE OR CARTRIDGE (MANIFOLD) DESIGN. EXCLUDES REGULATOR, PRESSURE, MEDICAL GAS ADMINISTRATION APPARATUS; REGULATOR, OXYGEN, BAROMETRIC CONTINUOUS FLOW; REGULATOR, OXYGEN DEMAND; REGULATOR, OXYGEN DILUTER DEMAND; AND VALVE(1), FLUID PRESSURE REGULATING, AIRCRAFT.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
7860002-101 | 92003 | A | 5 | 9 | 5 | MB | ||
7860002-102 | 92003 | A | 3 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
92003 | PARKER HANNIFIN CORPORATION DIV AERO |
Federal Supply Class
Title
VALVES, POWERED
Inclusions:
INCLUDES ELECTRIC MOTOR OPERATED VALVES; HYDRAULIC OPERATED VALVES; SOLENOID OPERATED VALVES.
Exclusions:
EXCLUDES ENGINE INTAKE AND EXHAUST VALVES (FSC 2990, 2815); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AGAV | END ITEM IDENTIFICATION | 13F7-15-3 FIG 9-2; C-17 ACFT |
FEAT | SPECIAL FEATURES | MANUFACTURERS SUGGESTED NAME IS VALVE, PRIMARY DIVE AND CLIMB; FLUID MEDIA IS GASEOUS NITROGEN (GN2), JET FUEL VAPORS, AND AIR; PRESSURES: OPERATING (CLIMB) CRACK 0.7 PSID MIN., FULL FLOW 1.0 PSID MAX., OPERATING (DIVE) CRACK M0.150 PSID MIN., FULL FLOW M0.80 PSID MAX; CHECK OUT PRESSURE 5.0 PSID MAX., TO SENSING PORT; RATED FLOW (CLIMB) 7.0 SQ IN., PRIMARY AND 5.4 SQ IN., SECONDARY; RATED FLOW (DIVE) 19.3 SQ. IN, 16.3 SQ IN. SECONDARY; TEMPS: AMBIENT -65 TO +160 DEF FEH (OPERATIONAL), FLUID -65 TO +120 DEG FEH; WT 23 LB MAX |
ACKL | MEDIA FOR WHICH DESIGNED | AIR |
ADZJ | MOUNTING FACILITY | BOLTS AND BRACKET |
AEVR | VALVE LOADING METHOD | SPRING |
ADQZ | END CONNECTION QUANTITY | 2 |
ADQU | FLOW CONTROL DEVICE | DIAPHRAGM |