National Stock Number (NSN) Output Data
Definition:
A MANUALLY OR POWER OPERATED VALVE HAVING THREE OR MORE PORTS. THE DIRECTION OF THE FLOW THROUGH THE VARIOUS PORTS IS CONTROLLED BY EITHER ONE OR MORE RECIPROCATING SLIDE(S) OR SPOOL(S) WITH RECESS AREAS WHICH MATE WITH PORTS IN AN INTEGRAL OR REPLACEABLE PORTED SLEEVE, OR ONE OR MORE POPPET(S). IT IS DESIGNED TO CHANGE THE DIRECTION OF FLUID FLOW FROM ONE VALVE PORT TO ANOTHER. AN OFF (NO FLOW) POSITION IS NOT A FLOW PATTERN. THE VALVE IS DESIGNED TO ACTUATE VARIOUS COMPONENTS OF A FLUID SYSTEM. A POWER OPERATED VALVE MAY HAVE A MANUAL OVERRIDE. FOR ITEMS WHICH STOP, START, OR CHANGE THE FLOW OF FLUID, SEE: VALVE, SOLENOID. EXCLUDES VALVE, PLUG. SEE ALSO SERVOVALVE, HYDRAULIC; BODY SECTION, WORKING, LINEAR DIRECTIONAL CONTROL VALVE; AND VALVE ASSEMBLY.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
7010393 | 0MLM6 | M | 3 | 2 | C | ZZ | ||
RD-516EA5A4B2-T | 29260 | A | 5 | 2 | 5 | ZZ | ||
RD-516EA5A4B2-22 | 29260 | A | 5 | 9 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
0MLM6 | MARINE CORPS SYSTEMS COMMAND PROGRAM |
29260 | PRINCE MANUFACTURING CORPORATION. |
Federal Supply Class
Title
VALVES, POWERED
Inclusions:
INCLUDES ELECTRIC MOTOR OPERATED VALVES; HYDRAULIC OPERATED VALVES; SOLENOID OPERATED VALVES.
Exclusions:
EXCLUDES ENGINE INTAKE AND EXHAUST VALVES (FSC 2990, 2815); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AQLR | VALVE OPERATION METHOD | HYDRAULIC |
CYGZ | SPOOL POSITION QUANTITY | 1 |
AWLS | CONNECTION TYPE | THREADED INTERNAL TUBE |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | DIRECTIONAL CONTROL VALVE |
ADSY | VALVE DISCHARGE FLOW RATE | 25.0 GALLONS PER MINUTE |
FEAT | SPECIAL FEATURES | NONBLOCK SPOOL TYPE PROVIDING AND INLET AND AN OUTLET, AN INTEGAL ADJUSTABLE RELIEF VALVE AND SPRING LOADED SPOOL;SPOOL TRAVELS 5/16 PLUS/MINUS 1/16 BETWEEN POSITIONS;RELIEF VALVE ADUSTABLE FROM 1500 PSI THRU 3000 PSI;MINIMUM OPER TEMP IS MINUS 65.0 FAHR;OVERALL LENGTH 9.750 INCHES;OVERALL WIDTH IS 5.500 INCHES;OUTLET TUBE SZ 0.750 INCHES AND 2 INLET TUBE SZ IS 0.630 INCHES |
AGAV | END ITEM IDENTIFICATION | 2350-01-080-9088 AND 2350-01-458-7550 |
CYHB | SPOOL QUANTITY | 1 |
ADQZ | END CONNECTION QUANTITY | 3 |
CQCJ | MAXIMUM OPERATING PRESSURE AND MEDIA FOR WHICH DESIGNED | 3000.0 POUNDS PER SQUARE INCH OIL, LUBRICATING, DIESTER BASE AND 3000.0 POUNDS PER SQUARE INCH HYDRAULIC FLUID, PETROLEUM BASE |
CRWH | MAXIMUM OPERATING TEMP AND MEDIA FOR WHICH DESIGNED | 225.0 DEG FAHRENHEIT OIL, HYDRAULIC |
TMQY | FURNISHED ITEMS AND QUANTITY | 1 RELIEF VALVE |
CBBL | FEATURES PROVIDED | BULKHEAD MOUNTED AND SPRING LOADED |