Part Number
Part Number:
NSN:
NIIN:
Item Name:
RESISTOR , THERMAL
Definition:
A THERMALLY SENSITIVE RESISTOR WHOSE PRIMARY FUNCTION IS TO EXHIBIT A CHANGE IN ELECTRICAL RESISTANCE WITH A CHANGE IN BODY TEMPERATURE. ITEM MAY BE MOUNTED IN A PROBE OR HOUSING. FOR BALLAST TUBE TYPE RESISTORS, SEE RESISTOR (1), CURRENT REGULATING. EXCLUDES TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE AND TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
CAGE Information
Code | Company |
---|---|
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.6 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 8.2 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.0/+8.0 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -75.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEHX | MAXIMUM POWER DISSIPATION RATING | 250.00 MILLIWATTS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 54.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -65.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.3/+5.3 5TH RESISTANCE-TEMPERATURE POINT |
STYL | STYLE DESIGNATOR | ROD |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 5.0 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -25.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 16.7 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -6.6/+6.6 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.7 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.2/+9.2 9TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -6.7/+6.7 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 12.0 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.3/+8.3 1ST RESISTANCE-TEMPERATURE POINT |
ADAQ | BODY LENGTH | 0.585 INCHES NOMINAL |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.2/+7.2 7TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 22.3 KILOHMS 10TH RESISTANCE-TEMPERATURE POINT |
ADAR | BODY OUTSIDE DIAMETER | 0.200 INCHES NOMINAL |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -8.5/+8.5 8TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.4/+7.4 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 5.4 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
CQWD | ZERO POWER RESISTANCE | 10.000 KILOHMS |
AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.70 |
AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 20.0 KILOHMS 9TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0/+5.0 |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 14.1 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.1/+10.1 10TH RESISTANCE-TEMPERATURE POINT |