National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
REGULATOR , TEMPERATURE AND PRESSU
Definition:
A SELF SENSORED REGULATOR DESIGNED TO AUTOMATICALLY REGULATE STEAM FLOW AND PRESSURE ACCORDING TO PREDETERMINED PRESSURE OR TEMPERATURE SETTING. DESIGNED TO OPEN OR CLOSE A VALVE WHEN EXCESSIVE OR REDUCED PRESSURE OR TEMPERATURE IS DETECTED. VALVE BODY NOT INCLUDED. SEE ALSO REGULATOR (1), THERMOSTATIC TEMPERATURE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
11-024-009 | 43990 | A | 5 | 9 | E | AX | ||
R24-A00-RNSA | 43990 | A | 3 | 2 | E | ZZ |
CAGE Information
Code | Company |
---|---|
43990 | NORGREN C A CO |
Federal Supply Class
Title
VALVES, NONPOWERED
Inclusions:
INCLUDES AUTOMATIC NONPOWERED VALVES; GATE, GLOBE, ANGLE, CHECK, AND RELIEF VALVES; COCKS.
Exclusions:
EXCLUDES FIRE HYDRANTS (FSC 4210); SPRINKLER HEADS (FSC 4210); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AWTP | SPRING OPERATED PRESSURE RELIEF | PROVIDED |
AWTN | OPERATING TEMP RATING | 175.0 DEG FAHRENHEIT MAXIMUM |
ADSV | OPENING PRESSURE SETTING | 400.0 POUNDS PER SQUARE INCH |
AWPA | THERMOSTAT TYPE | ANY ACCEPTABLE |
ADQU | FLOW CONTROL DEVICE | BY-PASS |
AGWM | LARGEST OUTSIDE DIAMETER | 1.250 INCHES NOMINAL |