Part Number
Part Number:
NSN:
NIIN:
Item Name:
INSULATION SLEEVING , ELECTRICAL , S
Definition:
A RIGID OR FLEXIBLE TUBING HAVING OTHER THAN UNIFORM FABRICATED SHAPES OR FORMS. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS OR BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE ITEMS. EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; AND INSULATION SLEEVING, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AGAC | FIRST BRANCH WALL THICKNESS | ANY ACCEPTABLE AS SUPPLIED |
AGAH | MAIN BODY OVERALL LENGTH | 3.250 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
HUES | COLOR | BLACK |
AFZT | DISTANCE FROM CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 1.500 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH/ |
AFZT | DISTANCE FROM CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | ANY ACCEPTABLE AS SUPPLIED |
FEAT | SPECIAL FEATURES | ADHESIVE SEALANT APPLIED TO EACH END |
AGAH | MAIN BODY OVERALL LENGTH | ANY ACCEPTABLE AS SUPPLIED |
AGAB | MAIN BODY WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
MATL | MATERIAL | PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP |
AGAC | FIRST BRANCH WALL THICKNESS | 0.080 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
STYL | STYLE DESIGNATOR | TRANSITION-T |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.400 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 165.0 NOMINAL AS SUPPLIED |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.800 INCHES MINIMUM AS SUPPLIED |
AFZU | MAIN BODY INSIDE DIAMETER | 0.600 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAB | MAIN BODY WALL THICKNESS | ANY ACCEPTABLE AS SUPPLIED |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 90.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
FLEX | FLEXIBILITY | SEMIRIGID |
AFZU | MAIN BODY INSIDE DIAMETER | 1.200 INCHES MINIMUM AS SUPPLIED |