National Stock Number (NSN) Output Data
Definition:
A CABINETLIKE ITEM USUALLY WITH A FRONT WORK AREA AND CONSISTING OF THE NECESSARY INSTRUMENTATION, MECHANICAL AND ELECTRICAL FACILITIES FOR COMPONENT MOUNTING. DESIGNED TO TEST EFFICIENCY OF PACKAGED HYDRAULIC AND PNEUMATIC PRESSURE AND ELECTRIC POWER GENERATING EQUIPMENT. COMPONENT UNDER TEST IS EQUIPPED WITH SELF CONTAINED POWER SOURCE. EXCLUDES TEST STAND, HYDRAULIC SYSTEM COMPONENT; TEST STAND, ELECTRIC; AND HYDRAULIC SYSTEM COMPONENTS.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
SE2905-3 | 81755 | A | 3 | 2 | 4 | MB | ||
SE2905 | 81755 | A | 5 | 2 | 4 | MB | ||
SE2905-1 | 81755 | A | 5 | 2 | 4 | MB |
CAGE Information
Code | Company |
---|---|
81755 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
AIRCRAFT MAINTENANCE AND REPAIR
Inclusions:
INCLUDES MAINTENANCE STANDS DESIGNED FOR SUPPORT OF AIRCRAFT ASSEMBLIES DURING REPAIR OR OVERHAUL; TEST STANDS AND TEST EQUIPMENT SPECIALLY DESIGNED FOR MAINTENANCE AND REPAIR OF AIRCRAFT COMPONENTS SUCH AS: ENGINES, GENERATORS, HYDRAULIC SYSTEMS, ARMAMENT, AUTOMATIC PILOT, FIRE CONTROL, FLIGHT CONTROL, AND NAVIGATIONAL SYSTEMS.
Exclusions:
EXCLUDES HAND TOOLS; AIRFIELD MAINTENANCE PLATFORMS; BASIC TYPES OF ELECTRICAL AND ELECTRONIC TEST INSTRUMENTS, INCLUDING THOSE SPECIALLY DESIGNED, SUCH AS AMMETERS, VOLTMETERS OHMMETERS, MULTIMETERS, AND SIMILAR INSTRUMENTS, AS SHOWN IN THE INDEXES TO THE FSC; TEST APPARATUS USED FOR BOTH COMMUNICATIONS AND OTHER ELECTRICAL AND ELECTRONIC EQUIPMENT.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AYJM | ACCUMULATOR | NOT INCLUDED |
ANCY | HORSEPOWER RATING | NOT RATED |
FCLS | FUNCTIONAL CLASSIFICATION | AA-9.2 |
CGYK | ENGINE DRIVEN HYDRAULIC PUMP TESTING DESIGN FEATURE | INCLUDED |
ALBY | USAGE DESIGN | AIRCRAFT HYDRAULIC SYSTEM OR INDIVIDUAL HYDRAULIC UNITS |
ACDC | CURRENT TYPE | AC OR DC |
ATPR | MAXIMUM SPEED RATING IN RPM | NOT RATED |
CGYM | PRESSURE MANIFOLD SUBCIRCUIT | NOT INCLUDED |
AAYJ | HYDRAULIC FLUID FLOW RATE | NOT RATED |
CGYL | FLOW CAPACITY RATING | NOT RATED |
FEAT | SPECIAL FEATURES | 99.000 IN L,46.000 IN D,64.000 IN H |
CHGR | PRESSURE/SUCTION HOSE | NOT INCLUDED |
FTLD | FUNCTIONAL DESCRIPTION | USED TO PROOF PRESSURE AND BENCH TEST AIR CONDITIONING SYSTEMS |
CHGQ | FILTERING SYSTEM | NOT INCLUDED |
AMQY | INSTALLATION DESIGN | FIXED OR PORTABLE |
RDAL | REFERENCE DATA AND LITERATURE | T.O.33D2-18-3-1 |
BJDW | MAXIMUM OPERATING PRESSURE | 400.0 POUNDS PER SQUARE INCH |
ATJK | POWER SOURCE | ELECTRIC MOTOR |
AKCV | DRIVE TYPE | ELECTRIC MOTOR |
ELEC | VOLTAGE IN VOLTS | 115.0 AND 28.0 |
FAAZ | PHASE | SINGLE |
FREQ | FREQUENCY IN HERTZ | 400.0 |
BGST | PRESSURE RATING | 100.0 POUNDS PER SQUARE INCH MINIMUM AND 400.0 POUNDS PER SQUARE INCH MAXIMUM |