National Stock Number (NSN) Output Data
Definition:
DEFINITE LENGTHS OF TWO OR MORE ELECTRICAL WIRES OR SIMILIAR CONDUCTORS (EXCEPT CABLE OR MULTICONDUCTOR CORD) WHICH ARE NOT JACKETED, BOUND, OR LACED TOGETHER, BUT WHICH HAVE AT LEAST ONE OF THEIR ENDS PROCESSED IN A SINGLE COMMON TERMINATION OR FITTING. FOR AN ITEM CONSISTING OF A CONNECTOR, RECEPTACLE, ELECTRICAL HAVING TERMINATION WIRES OF LENGTH FOUR INCHES (101.6MM) OR LESS, SEE CONNECTOR, RECEPTACLE, ELECTRICAL. SEE ALSO CABLE ASSEMBLY (AS MODIFIED); WIRING HARNESS; AND LEAD, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
495297-2 | 00779 | A | 3 | 2 | 2 | SE | ||
921067-34 | 82577 | A | 5 | 2 | 4 | SE |
CAGE Information
Code | Company |
---|---|
00779 | TYCO ELECTRONICS CORPORATION |
82577 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
AIRCRAFT MAINTENANCE AND REPAIR
Inclusions:
INCLUDES MAINTENANCE STANDS DESIGNED FOR SUPPORT OF AIRCRAFT ASSEMBLIES DURING REPAIR OR OVERHAUL; TEST STANDS AND TEST EQUIPMENT SPECIALLY DESIGNED FOR MAINTENANCE AND REPAIR OF AIRCRAFT COMPONENTS SUCH AS: ENGINES, GENERATORS, HYDRAULIC SYSTEMS, ARMAMENT, AUTOMATIC PILOT, FIRE CONTROL, FLIGHT CONTROL, AND NAVIGATIONAL SYSTEMS.
Exclusions:
EXCLUDES HAND TOOLS; AIRFIELD MAINTENANCE PLATFORMS; BASIC TYPES OF ELECTRICAL AND ELECTRONIC TEST INSTRUMENTS, INCLUDING THOSE SPECIALLY DESIGNED, SUCH AS AMMETERS, VOLTMETERS OHMMETERS, MULTIMETERS, AND SIMILAR INSTRUMENTS, AS SHOWN IN THE INDEXES TO THE FSC; TEST APPARATUS USED FOR BOTH COMMUNICATIONS AND OTHER ELECTRICAL AND ELECTRONIC EQUIPMENT.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CXDG | STRAND AWG SIZE PER CONDUCTOR | 32 ALL CONDUCTORS |
ZZZV | FSC APPLICATION DATA | TEST SET,FLIGHT CONTROL SYSTEM,NOT INTEGRAL WITH EQUIPMENT |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 20 AWG ALL CONDUCTORS |
AMQN | CONDUCTOR QUANTITY | 4 |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
APYS | CONDUCTOR LENGTH | 8.500 INCHES NOMINAL ALL CONDUCTORS |