Definition:
SEE ALSO STAND, MAINTENANCE, RAIL TYPE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
ST93151 | 55820 | A | 3 | 2 | 4 | SB |
CAGE Information
Code | Company |
---|---|
55820 | HAMILTON SUNDSTRAND CORPORATION DIV |
Federal Supply Class
Title
AIRCRAFT MAINTENANCE AND REPAIR
Inclusions:
INCLUDES MAINTENANCE STANDS DESIGNED FOR SUPPORT OF AIRCRAFT ASSEMBLIES DURING REPAIR OR OVERHAUL; TEST STANDS AND TEST EQUIPMENT SPECIALLY DESIGNED FOR MAINTENANCE AND REPAIR OF AIRCRAFT COMPONENTS SUCH AS: ENGINES, GENERATORS, HYDRAULIC SYSTEMS, ARMAMENT, AUTOMATIC PILOT, FIRE CONTROL, FLIGHT CONTROL, AND NAVIGATIONAL SYSTEMS.
Exclusions:
EXCLUDES HAND TOOLS; AIRFIELD MAINTENANCE PLATFORMS; BASIC TYPES OF ELECTRICAL AND ELECTRONIC TEST INSTRUMENTS, INCLUDING THOSE SPECIALLY DESIGNED, SUCH AS AMMETERS, VOLTMETERS OHMMETERS, MULTIMETERS, AND SIMILAR INSTRUMENTS, AS SHOWN IN THE INDEXES TO THE FSC; TEST APPARATUS USED FOR BOTH COMMUNICATIONS AND OTHER ELECTRICAL AND ELECTRONIC EQUIPMENT.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFPM | ASSEMBLY FORM | RIGID |
AGAV | END ITEM IDENTIFICATION | F16A/B ACFT,AGE. |
SUPP | SUPPLEMENTARY FEATURES | TEST STAND FIXTURE 30"L X 24"W X 35.5"H, BOOM ASSY 66"L X 6"W X 90"H, CONTROL CONSOLE ASSY 66.19"L X 44.44"W X 53.50H, WEIGHTS - TEST STAND FIXTURE 580LBS, JET FUEL STARTER TURBINE 60LBS, ACCESSORY DRIVE GEARBOX 85LBS, WATER DYNAMOMETER 70LBS, STARTER 35LBS, CONTROL CONSOLE ASSY 450LBS |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | TEST STAND, JET FUEL STARTER |
FEAT | SPECIAL FEATURES | TEST CELL CONTAINS THE TEST STAND FIXTURE. A REDUCTION DRIVE GEARBOX, A STARTER MOTOR, FUEL SYSTEM VALVES AND ASSOC WIRING AND PLUMBING ARE MOUNTED ON THE TEST STAND FIXTURE. A WATER DYNAMOMETER MOUNTED ON THE TEST STAND PROVIDES POWER LOADING FOR THE TURBINE. AN EGT THERMOCOUPLE DUCT AND CUSTOM EXHAUST DUCT ASSY CONNECTS THE TURBINE WITH EXISTING FACILITY DUCTS. A BOOM MOUNTED JUNCTION BOX PROVIDES FOR AIR/ELECTRICAL CONNECTION WITH THE TEST STAND FIXTURE. A BOOM C/O WIRING AND HOSES CONNECTS THE BOOM JUNCTION BOX WITH THE WIRING DUCT FOR THE CONTROL ROOM. TEST STAND FUEL AND WATERBRAKE CONTROLS ARE IN THE TEST CELL. AN INTERFACE (BOX) PROVIDES THE CONTROL INTERFACE BETWEEN THE CONTROL ROOM AND TEST CELL |
FTLD | FUNCTIONAL DESCRIPTION | USED TO FUNCTIONALLY TEST THE JET FUEL STARTER |
RDAL | REFERENCE DATA AND LITERATURE | T.O. 33D4-6-634-1, -4 |
CGYB | WORK HOLDING DEVICE POSITION ADJUSTABILITY | ADJUSTABLE |