National Stock Number (NSN) Output Data
Definition:
A GROUP OF ITEMS CONTAINING A CONSOLE AND/OR PERPHERAL EQUIPMENT SPECIFICALLY DESIGNED TO PROVIDE APPROPRIATE INSTRUMENTATION AND DATA ACQUISITION/CONTROL LOGIC FOR TESTING OF COMPONENTS OF AN AIRCRAFT FUEL SYSTEM.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
2755000 | 06848 | A | 5 | 9 | 2 | MB | ||
TTU-498/F | 80058 | M | 5 | 9 | 4 | ZZ | ||
2756000 | 06848 | A | 3 | 2 | 4 | ZZ | ||
PWA53111-3 | 77445 | A | 5 | 2 | 4 | MB | ||
PWA53111-1 | 77445 | A | 5 | 9 | 4 | MB |
CAGE Information
Code | Company |
---|---|
06848 | HONEYWELL INTERNATIONAL INC. AEROSPA |
80058 | JOINT ELECTRONICS TYPE DESIGNATION S |
77445 | UNITED TECHNOLOGIES CORPORATION DBA |
Federal Supply Class
Title
AIRCRAFT MAINTENANCE AND REPAIR
Inclusions:
INCLUDES MAINTENANCE STANDS DESIGNED FOR SUPPORT OF AIRCRAFT ASSEMBLIES DURING REPAIR OR OVERHAUL; TEST STANDS AND TEST EQUIPMENT SPECIALLY DESIGNED FOR MAINTENANCE AND REPAIR OF AIRCRAFT COMPONENTS SUCH AS: ENGINES, GENERATORS, HYDRAULIC SYSTEMS, ARMAMENT, AUTOMATIC PILOT, FIRE CONTROL, FLIGHT CONTROL, AND NAVIGATIONAL SYSTEMS.
Exclusions:
EXCLUDES HAND TOOLS; AIRFIELD MAINTENANCE PLATFORMS; BASIC TYPES OF ELECTRICAL AND ELECTRONIC TEST INSTRUMENTS, INCLUDING THOSE SPECIALLY DESIGNED, SUCH AS AMMETERS, VOLTMETERS OHMMETERS, MULTIMETERS, AND SIMILAR INSTRUMENTS, AS SHOWN IN THE INDEXES TO THE FSC; TEST APPARATUS USED FOR BOTH COMMUNICATIONS AND OTHER ELECTRICAL AND ELECTRONIC EQUIPMENT.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AGAV | END ITEM IDENTIFICATION | F100-PW-220 ACFT ENGINE |
FEAT | SPECIAL FEATURES | 480.0 VAC,60.0 HZ,3-PHASE,9.5 KVA; OUTPUT/OPERATING CHARACTERISTICS: FUEL: 0-1400 PSIG,0-36 GPM,85 DEG F PORM 2 DEG; PNEUMATIC: SHOP AIR: 100 PSIG,20 SCFM; PURGE AIR: 300 SCFM; HIGH PRESSURE AIR: 750 PSIG,10 SCFM,HIGH PRESSURE GN2: 200 PSIG,5 SCFM; TEST STATION PROVIDES TO UUT GN2: 50 PSIA; WATER: HOT WATER,40 PSIG,2 GPM,140 DEG F; COLD WATER: 40 PSIG,10 GPM,55 DEG F; COMPUTER CONTROLLED; 11.000 FT W,8.000 FT D,8.000 FT H; FIXED MOUNT |
FTLD | FUNCTIONAL DESCRIPTION | USED FOR FAULT ISOLATION,AND FINAL SERVICE ACCEPTANCE ON ASSEMBLIES/SUB-ASSEMBLIES OF THE AUGMENTOR PUMP CONTROLLER |
RDAL | REFERENCE DATA AND LITERATURE | SERD NO. 4802 |