INSULATION SLEEVING , ELECTRICAL

Definition:

A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.

CAGE Information

Code Company
36378 RAYTHEON TECHNICAL SERVICES COMPANY

Federal Supply Class

Title

ELECTRICAL INSULATORS AND INSULA

Inclusions:

INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQBC MINIMUM TENSILE STRENGTH 3810 POUNDS PER SQUARE INCH
CQBC MINIMUM TENSILE STRENGTH 3810 POUNDS PER SQUARE INCH
ABJH TEMP RATING -20.0 DEG CELSIUS AND 105.0 DEG CELSIUS
HUES COLOR BLACK
FLEX FLEXIBILITY FLEXIBLE
ABHP OVERALL LENGTH ANY ACCEPTABLE
MATL MATERIAL PLASTIC, POLYVINYL CHLORIDE
AARG RELIABILITY INDICATOR NOT ESTABLISHED
UKBG DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS 759.0 VOLTS PER MIL /0.001 INCH/
AAGT WALL THICKNESS 0.020 INCHES NOMINAL
STYL STYLE DESIGNATOR NONSHRINKABLE
FEAT SPECIAL FEATURES ZIPPER TRACK
AARX INSIDE DIAMETER 0.750 INCHES NOMINAL
ADZC ENVIRONMENTAL PROTECTION FLAME RESISTANT AND MILDEW RESISTANT