Part Number
Part Number:
NSN:
NIIN:
Item Name:
SATURABLE REACTOR
Definition:
AN ITEM WHOSE INDUCTANCE VALUE IS CONTROLLED BY ELECTRICAL MEANS. IT DEPENDS ON THE ACTION OF THE ELECTROMAGNET FLUX PRODUCED BY THE CONTROL WINDING UPON THE EFFECTIVE PERMEABILITY OF THE CORE. IT CONTAINS TWO OR MORE WINDINGS, AT LEAST ONE OF WHICH MUST BE A CONTROL WINDING. FOR ITEMS DESIGNED TO BE USED IN CONJUNCTION WITH A RECTIFIER(S) FOR AMPLIFICATION PURPOSES, SEE AMPLIFIER, MAGNETIC.
CAGE Information
Code | Company |
---|---|
63743 | WARD LEONARD ELECTRIC COMPANY INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ADAQ | BODY LENGTH | 3.625 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.469 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAT | BODY WIDTH | 2.000 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 4.344 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.169 INCHES NOMINAL SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
ABHP | OVERALL LENGTH | 3.000 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 1 TERMINAL BLOCK W/SCREWS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 CONTROL SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPEN |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.094 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |