Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
MOTOR , ALTERNATING CURRENT

Definition:

A MOTOR WHICH IS DESIGNED FOR OPERATION FROM AN ALTERNATING CURRENT SOURCE. SEE ALSO MOTOR, CONTROL.

CAGE Information

Code Company
13499 ROCKWELL COLLINS INC. DBA GOVERNMENT

Federal Supply Class

Title

MOTORS, ELECTRICAL

Inclusions:

Exclusions:

EXCLUDES STARTING MOTORS FOR ENGINES.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AXGY MOUNTING METHOD FACE
AXGY MOUNTING METHOD FACE
ABWV SHAFT DIAMETER 0.248 INCHES NOMINAL FIRST END
AKCT SHAFT ROTATION DIRECTION CLOCKWISE SINGLE END
CWGQ CONNECTION TYPE AND VOLTAGE RATING IN VOLTS 115.0 LINE TO NEUTRAL SINGLE INPUT
ANPZ INCLOSURE FEATURE TOTALLY INCLOSED
CBBL FEATURES PROVIDED HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION
CWFQ MOUNTING FACILITY CIRCLE DIAMETER 1.500 INCHES
BKPQ INCLOSURE SPECIFICATION COMMERCIAL
TTQY TERMINAL TYPE AND QUANTITY 4 WIRE LEAD
CWHZ SHAFT END CHARACTERISTIC A1 SINGLE STYLE SINGLE END
AXHR MOUNTING FACILITY TYPE AND QUANTITY 3 THREADED HOLE
CWFX ROTOR SPEED RATING IN RPM 3200.0 SINGLE FULL LOAD
FREQ FREQUENCY IN HERTZ 60.0 INPUT
AAJV OVERALL WIDTH 2.500 INCHES
AAJU OVERALL LENGTH 3.469 INCHES
FAAZ PHASE SINGLE INPUT
CWGL CURRENT RATING IN AMPS 0.200 SINGLE INPUT
AAJT OVERALL HEIGHT 2.500 INCHES
CWCS LENGTH OF SHAFT FROM HOUSING 0.281 INCHES SINGLE END
AKPS DUTY CYCLE CONTINUOUS
BKPB CURRENT RATING METHOD LOAD
AXCP WINDING TYPE INDUCTION-SPLIT PHASE
CNXS POWER RATING 0.0125 HORSEPOWER OUTPUT
ABWV SHAFT DIAMETER 0.249 INCHES NOMINAL SECOND END
CWDY TEMP RATING -55.0 OPERATING DEG CELSIUS AND 70.0 OPERATING DEG CELSIUS AND 50.0 AMBIENT DEG CELSIUS
BFMF COOLING METHOD NONVENTILATED

Similar Parts

5051662004 , 5051662004 , 6105-00-330-9740 , 6105003309740 , 003309740