Part Number
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OF MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
CAGE Information
Code | Company |
---|---|
05869 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.095 NOMINAL MILS AND 0.105 NOMINAL CENTIMETERS |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.095 NOMINAL MILS AND 0.105 NOMINAL CENTIMETERS |
AAPN | SECTION QUANTITY | 1 |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 2.0 PERCENT, RATED AMPERES C AND BETTER FLOORING |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AXGY | MOUNTING METHOD | TERMINAL |
ADAT | BODY WIDTH | 0.180 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 9000.0 NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
CBME | CUBIC MEASURE | 0.054 CUBIC INCHES |
AEDZ | SHAFT BEARING TYPE | SLEEVE |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.195 INCHES MINIMUM AND 0.205 INCHES MAXIMUM |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -50.0/+50.0 SINGLE SECTION |
AAQL | BODY STYLE | RECTANGULAR |
ABWV | SHAFT DIAMETER | 0.055 INCHES MINIMUM AND 0.060 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABXF | SHAFT LENGTH | 0.030 INCHES MAXIMUM |
AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES |
ADAU | BODY HEIGHT | 0.482 INCHES MINIMUM AND 0.508 INCHES MAXIMUM |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.5 7TH SECONDARY QUALITY |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CLUTCH |
APXH | TERMINAL LOCATION | REAR END |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 9000.0 NOMINAL |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0/+5.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
ABJT | TERMINAL LENGTH | 0.172 INCHES MINIMUM AND 0.202 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
ADAQ | BODY LENGTH | 0.522 INCHES MINIMUM AND 0.538 INCHES MAXIMUM |