Part Number
Part Number:
NSN:
NIIN:
Item Name:
REACTOR
Definition:
A COIL OR COILS USUALLY CONSTRUCTED WITH CORES HAVING LOW MAGNETIC RELUCTANCE, WHOSE PRIMARY PURPOSE IS TO FURNISH AN INDUCTIVE IMPEDANCE IN POWER OR AUDIO FREQUENCY CIRCUIT RANGING FROM ZERO TO 20 KILOHERTZ (KILOCYCLES). INCLUDES AUDIO FREQUENCY AND POWER FILTER CHOKES, AUDIO REACTORS AND SWINGING CHOKES. DOES NOT INCLUDE TRANSFORMERS OR COILS USED ABOVE AUDIO FREQUENCY RANGE. EXCLUDES SATURABLE REACTOR. FOR REACTORS WITH AIR CORES, SEE COIL (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
01961 | PULSE ENGINEERING INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
ADAQ | BODY LENGTH | 0.670 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.375 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACYF | INDUCTANCE TYPE | FIXED |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 4.500 SINGLE COMPONENT SINGLE WINDING |
ACZB | FREQUENCY RATING | 15.8 KILOHERTZ NOMINAL SINGLE COMPONENT |
ADAU | BODY HEIGHT | 0.785 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | WEAPON SYTEM ESSENTIAL |
ABHY | TURN QUANTITY | 200 SINGLE COMPONENT SINGLE WINDING |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE WINDING |
ACYV | INDUCTANCE RATING | 80.00 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING |
AGAV | END ITEM IDENTIFICATION | HELICOPTER, SEARCH AND RESCUE, HH-60H; SPRUANCE CLASS DD (963); GENERAL PURPOSE ELECTRONIC TEST EQUIPMENT GPETE; HELICOPTER, USCG SEARCH AND RESCUE, HH-60J; HELICOPTER, CARRIER BASED ASW, SH-60F; AIRCRAFT, TOMCAT F-14; LOS ANGELES CLASS SSN (688); SUPPORT EQUIPMENT, B-1 AIRCRAFT; EMORY S. LAND CLASS AS |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |