Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , REED

Definition:

A RELAY CONSISTING OF AN ENERGIZING COIL AND A METALLIC REED SWITCH MECHANISM. THE REEDS SERVE AS BOTH CORE AND CONTACTS, WHICH ARE NOT HINGED OR PIVOTED AND WHICH MOVE BY FLEXURE WHEN ACTED UPON BY A MAGNETIC FIELD INDUCED BY ENERGIZATION OF THE COIL. IT MAY ALSO INCLUDE A BIASING MAGNET. THE BIASING MAGNET, EITHER AIDS OR OPPOSES THE MOVEMENT OF THE REEDS AND THE OPENING OR CLOSING OF THE CONTACTS. FOR ITEMS IN WHICH ACTUATION IS DEPENDENT ON THE RESONANT FREQUENCY OF THE REEDS SEE RELAY, RESONANT REED. EXCLUDES RELAY, ELECTROMAGNETIC.

CAGE Information

Code Company
96214 RAYTHEON COMPANY

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 250.0 MILLIAMPERES DC RESISTIVE LOAD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 24.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
ABMK OVERALL WIDTH 0.560 INCHES NOMINAL
APCN COIL QUANTITY 1
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 26.0 DC
APNA WINDING DC RESISTANCE RATING 1.25 KILOHMS NOMINAL SINGLE WINDING
ABHP OVERALL LENGTH 1.125 INCHES NOMINAL
ABKW OVERALL HEIGHT 0.550 INCHES NOMINAL
ADZC ENVIRONMENTAL PROTECTION HERMETIC
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
APNP DUTY TYPE CONTINUOUS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY

Similar Parts

537417-3 , 5374173 , 5945-00-517-9402 , 5945005179402 , 005179402