Part Number
Part Number:
NSN:
NIIN:
Item Name:
AMPLIFIER , MAGNETIC
Definition:
AN ITEM CONSISTING OF A SATURABLE REACTOR WHICH IS SPECIALLY DESIGNED TO BE USED IN CONJUNCTION WITH A RECTIFIER(S) FOR AMPLIFICATION PURPOSES. THE RECTIFIER(S) MAY OR MAY NOT BE AN INTEGRAL PART OF THE ITEM OF SUPPLY. THE ITEM MAY INCLUDE RESISTORS, CAPACITORS, AND/OR OTHER ELECTRICAL COMPONENTS.
CAGE Information
Code | Company |
---|---|
37695 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
AMPLIFIERS
Inclusions:
INCLUDES AUDIO AMPLIFIERS, COMPLEMENTARY AMPLIFIERS, AMPLIFIERS, OPERATIONAL AMPLIFIERS, POWER AMPLIFIERS, RADIO FREQUENCY AMPLIFIERS, SIGNAL AMPLIFIERS, VIDEO AMPLIFIERS, AND MAGNETIC AMPLIFIERS.
Exclusions:
EXCLUDES MULTI-FUNCTIONAL ITEMS SUCH AS AMPLIFIER-DETECTOR, AMPLIFIER-MIXER AND MICROCIRCUIT DEVICES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ADAT | BODY WIDTH | 1.312 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 670.00 AC MAJOR WET SINGLE COMPONENT SINGLE PRIMARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
CRMJ | WINDING POWER RATING | 3.5 WATTS SINGLE COMPONENT SINGLE SECONDARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ADAQ | BODY LENGTH | 2.188 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.250 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AARD | DUMMY TERMINAL QUANTITY (NON-CORE) | 1 |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE CONTROL |
CWJS | WINDING OPERATING VOLTAGE | 67.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 SECONDARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 CONTROL SINGLE COMPONENT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 7 TURRET |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |