Part Number
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OF MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
CAGE Information
Code | Company |
---|---|
96214 | RAYTHEON COMPANY |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 0.402 INCHES MINIMUM |
AAPN | SECTION QUANTITY | 1 |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.25 FREE AIR SINGLE SECTION |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-27208 SPECIFICATION |
ABWV | SHAFT DIAMETER | 0.075 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AXGY | MOUNTING METHOD | TERMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
ABXF | SHAFT LENGTH | 0.050 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.165 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 0.320 INCHES MAXIMUM |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 200.0 OHMS SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -50.0/+50.0 SINGLE SECTION |
AAQL | BODY STYLE | RECTANGULAR |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAU | BODY HEIGHT | 0.250 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.172 INCHES MINIMUM |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.165 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0/+5.0 SINGLE SECTION |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-27208/10 GOVERNMENT SPECIFICATION |
ADAQ | BODY LENGTH | 0.250 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE SINGLE ROW |