Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
98927 ELECTRONIC SPECIALTY CORP RELAY DIV

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
AKDX WINDING QUANTITY 2
TTQY TERMINAL TYPE AND QUANTITY 10 PIN ALL FUNCTIONS
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 26.5 VOLTS TEARDROP, TWO HOLES TYPE 4F ALL WINDINGS
APNA WINDING DC RESISTANCE RATING 1.0 KILOHMS NOMINAL ALL WINDINGS
APCN COIL QUANTITY 2
ABMK OVERALL WIDTH 0.410 INCHES MAXIMUM
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CRXH TIME DELAY 0.01 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
ABHP OVERALL LENGTH 1.180 INCHES MAXIMUM
ADZC ENVIRONMENTAL PROTECTION HERMETIC
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES DC RESISTIVE LOAD
ABKW OVERALL HEIGHT 0.612 INCHES MAXIMUM
APNP DUTY TYPE CONTINUOUS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CBBL FEATURES PROVIDED POLARIZED AND LATCHING CONTACTS
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.096 INCHES NOMINAL SINGLE MOUNTING FACILITY

Similar Parts