RELAY , THERMAL

Definition:

A RELAY SWITCH WHICH IS ACTUATED BY THE EFFECT OF INTERNAL HEAT GENERATED BY THE CURRENT IN ITS ENERGIZING CIRCUIT. FOR ITEMS ACTUATED BY AMBIENT, RATHER THAN INTERNAL TEMPERATURE CHANGES, SEE SWITCH, THERMOSTATIC.

CAGE Information

Code Company
56232 LOCKHEED MARTIN CORPORATION DBA LOCK

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ADAV OVERALL DIAMETER 1.275 INCHES NOMINAL
ADAV OVERALL DIAMETER 1.275 INCHES NOMINAL
CYCW DELAY TIME IN SECONDS 75.0 FIXED OPERATE NOMINAL
CYCS CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 250.0 AC AND 150.0 DC
CYCV HEATER POWER RATING IN WATTS 5.0
ADZC ENVIRONMENTAL PROTECTION HERMETIC
APFR CONTACT ARRANGEMENT SINGLE POLE, SINGLE THROW, NORMALLY OPEN
CYCU HEATER VOLTAGE RATING IN VOLTS 117.0
TTQY TERMINAL TYPE AND QUANTITY 4 PIN
ABHP OVERALL LENGTH 3.250 INCHES NOMINAL
CYCT CONTACT MAXIMUM CURRENT RATING IN AMPS 3.0 AC OR 3.0 DC
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 OCTAL BASE PLUG-IN