Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.500 INCHES |
ABCS | TERMINAL ROW QUANTITY | 1 |
AMPS | CURRENT RATING IN AMPS | 40.0 |
CQCW | FEEDTHRU CONNECTION END TYPE | 600 BOTH ENDS SINGLE COMBINATION |
ABGN | BOARD OVERALL LENGTH | 3.375 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.312 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 2200.0 |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-M-14,TYPE MAI-60 MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
CRZR | FEEDTHRU TERMINAL QUANTITY | 6 SINGLE COMBINATION |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.250 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 1.000 INCHES |
ABGP | BOARD OVERALL WIDTH | 0.625 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.375 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.875 INCHES |
CWLN | TERMINAL DESIGN | VERTICAL FEEDTHRU |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
MATT | MATERIAL | PLASTIC POLYESTER BOARD AND GLASS FIBER BOARD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT |
ABGS | BASE THICKNESS | 0.500 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |