Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
C0426 | EADS DEUTSCHLAND T/A CASSIDIAN ELECT |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
AKDX | WINDING QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 390.0 OHMS NOMINAL SINGLE WINDING |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CRXH | TIME DELAY | 0.002 SECONDS MAXIMUM FIXED OPERATE TIME |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
ABHP | OVERALL LENGTH | 0.265 INCHES MAXIMUM |
APCN | COIL QUANTITY | 1 |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | AIR |
ADAV | OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 25.6 MILLIAMPERES DC SINGLE WINDING |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
CRXH | TIME DELAY | 0.0015 SECONDS MAXIMUM FIXED RELEASE TIME |
CBME | CUBIC MEASURE | 0.009 CUBIC INCHES |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
ADTV | CASE MATERIAL | METAL |