Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
GENERATOR , PULSE

Definition:

AN ELECTRONIC DEVICE WHICH DEVELOPS A DISCONTINUOUS ELECTRICAL POTENTIAL WITH AN ABRUPT RATE OF CHANGE OF VOLTAGE WHICH DETERMINES THE HARMONIC CONTENT OF THE PULSE TRAIN. THE DURATION OF A SINGLE PULSE OUTPUT IS RELATIVELY SHORT COMPARED TO THE TIME OF THE RECURRENCE CYCLE. SEE ALSO GENERATOR, SINGLE PULSE; AND GENERATOR, ELECTRONIC MARKER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
7093163G1 03538 A 3 2 X XX
7093163G1 24446 A 5 2 X XX
TD-516/FPS-6 80058 M 5 2 4 MC

CAGE Information

Code Company
03538 LOCKHEED MARTIN CORPORATION DBA MS2
24446 GENERAL ELECTRIC CO
80058 JOINT ELECTRONICS TYPE DESIGNATION S

Federal Supply Class

Title

MISCELLANEOUS COMMUNICATION EQUI

Inclusions:

INCLUDES MODEMS.

Exclusions:

EXCLUDES ELECTRONIC COUNTERMEASURES EQUIPMENT.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AGTA BASIC SHAPE STYLE RECTANGULAR OR SQUARE
BHTN IMPEDANCE RATING PER CHANNEL 68.000 OHMS OUTPUT CHANNEL
BHTB FREQUENCY PER CHANNEL 100.0 MEGAHERTZ MAXIMUM OPERATING CHANNEL
BHTZ SIGNAL DATA TYPE PER CHANNEL OUTPUT CHANNEL PULSE
ABKW OVERALL HEIGHT 1.880 INCHES NOMINAL
BHTT PULSE REPETITION RATE PER CHANNEL 400.000 CAPILLARY AT GRADUATION MARK NOMINAL CENTIMETERS
ABMK OVERALL WIDTH 3.220 INCHES NOMINAL
AMQY INSTALLATION DESIGN RACK
BJBQ OPERATING AC FREQUENCY IN HERTZ 60.0 NOMINAL SINGLE VOLTAGE
BHTB FREQUENCY PER CHANNEL 30.0 MEGAHERTZ MINIMUM OPERATING CHANNEL
BHTS POLARITY PER CHANNEL POSITIVE OUTPUT CHANNEL
BJBJ OUTPUT WAVE SHAPE SAWTOOTH
AFSU AVERAGE LIFE MEASUREMENT NOT RATED
ABHP OVERALL LENGTH 3.750 INCHES NOMINAL
BKFB EXTERNAL DC OPERATING VOLTAGE IN VOLTS 250.0 NOMINAL SINGLE VOLTAGE
BHTT PULSE REPETITION RATE PER CHANNEL 2.000 CAPILLARY ACTION NOMINAL CENTIMETERS
BHSX CIRCUIT CONSTRUCTION TYPE SOLID STATE
AKNA INCLOSURE TYPE ENCASED
BKFC EXTERNAL AC OPERATING VOLTAGE IN VOLTS 6.1 NOMINAL SINGLE VOLTAGE
BHTP PULSE DURATION PER CHANNEL 3.000 MICROSECONDS NOMINAL OUTPUT CHANNEL
BHTW PULSE PEAK AMPLITUDE PER CHANNEL 10.000 VOLTS OUTPUT CHANNEL
AGAV END ITEM IDENTIFICATION AN/FPS-6
FTLD FUNCTIONAL DESCRIPTION GENERATES A POSITIVE 50 V TRIGGER
FAAZ PHASE SINGLE

Similar Parts

7093163G1 , 7093163G1 , 5895-00-844-0703 , 5895008440703 , 008440703 , 7093163G1 , 7093163G1 , TD-516/FPS-6 ,