National Stock Number (NSN) Output Data
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
95 | 11237 | F | E | 8 | 3 | TX | ||
864537-0001 | 65597 | A | C | 1 | 5 | TX | ||
240-1317P12 | 49956 | A | C | 1 | 4 | 48 | AH | |
3184893-2 | 10001 | A | C | 1 | 5 | TX | A5 | |
030-109 | 60408 | A | C | 1 | 6 | ZZ | AC | |
CU6710A | 08143 | A | C | 1 | 5 | TX | ||
RV4ATSD502A | 06845 | A | C | 1 | 6 | TU | AW | |
JAIN056P502UA | 01121 | A | C | 1 | 6 | ZZ | AC | |
RV4NAYSD502A | 71450 | A | C | 1 | 6 | ZZ | AC | |
JA1N056P502UA | 01121 | A | C | 1 | 6 | ZZ | AC | |
5905006435626 | SCY13 | A | 5 | 9 | 9 | YP | ||
JA1N056S502A | 01121 | A | C | 1 | 6 | ZZ | AC | |
RV4NAXSD502A | 81349 | M | C | 1 | 6 | ZZ | AC | |
401428-8 | 28835 | A | C | 1 | 5 | TX | AF | |
RV4NAXSD502B | 81349 | M | C | 1 | 6 | ZZ | AC | |
RVNAYSD502A | 35627 | A | C | 1 | 5 | AJ | AO | |
JA1N100F502UA | 01121 | A | C | 1 | 6 | ZZ | AC | |
RV4NAY5D502A | 81349 | M | C | 1 | 6 | ZZ | AC | |
JA1N048P502AA | 01121 | A | 5 | 9 | 3 | 48 | ||
RV4NAYFE503B | 81349 | M | C | 1 | 6 | ZZ | AC | |
247-541129 | 89372 | F | C | 1 | 6 | ZZ | AC | |
JA1N048P502UA | 01121 | A | 5 | 9 | 3 | 48 | ||
40-1210P11 | 99562 | F | C | 1 | 5 | TX | AF | |
JA1N200P502AA | 01121 | A | C | 1 | 6 | ZZ | AC | |
MILR94-5 | 81349 | M | 4 | 1 | 3 | TX | ||
CU6710A | 01843 | A | C | 1 | 5 | TX | ||
RV4NAYSD502A | 81349 | M | 2 | 2 | 3 | TX | ||
JA2N055P502UA | 01121 | A | E | 8 | 4 | ZF | ||
5010053-7 | 05157 | A | E | 8 | 4 | 9Z | ||
240-1210P11 | 49956 | A | C | 1 | 4 | 48 | AH | |
RV4NAYSD502A | 01121 | A | C | 1 | 6 | ZZ | AC | |
380-2678-000 | 13499 | A | C | 1 | 5 | TX | ||
F820 | 57655 | A | C | 1 | 5 | 48 | AH | |
947753-5021 | 06481 | A | C | 1 | 6 | ZZ | AC | |
225001-41 | 37695 | A | C | 1 | 5 | TX | AF | |
240-1211P11 | 49956 | A | C | 1 | 5 | TX | ||
JHP124-035 | 02032 | H | C | 1 | 5 | TX | ||
RV4NAYSD502B | 81349 | M | C | 1 | 6 | ZZ | AC | |
6000-0500 | 24655 | A | C | 1 | 5 | TX | AF | |
240M0031P011 | 49956 | A | C | 1 | 5 | TX | ||
240-1316P12 | 49956 | A | C | 1 | 4 | 48 | AH | |
030 109 | 40608 | A | E | 8 | A | TX | ||
53C3-5000 | 12697 | A | 5 | 1 | 6 | 9Z | ||
416037-28 | 96214 | A | C | 1 | 5 | TX | AF | |
RV4NA4SD502B | 81349 | M | C | 1 | 6 | ZZ | AC | |
CU6710A | K4241 | A | 5 | 2 | 2 | ZK |
CAGE Information
Code | Company |
---|---|
01121 | ROCKWELL AUTOMATION INC. |
11237 | CTS CORP OF CALIFORNIA DBA CTS ELECT |
65597 | THALES ATM INC. |
49956 | RAYTHEON COMPANY DBA RAYTHEON |
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
60408 | LITWILLER MACHINE AND MFG |
08143 | AMEROLA INC |
06845 | RAYTHEON COMPANY DBA RAYTHEON |
71450 | CTS CORP |
SCY13 | E.C.A ETABLISSEMENT CENTRAL DES APPR |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
28835 | HOBART BROS CO |
35627 | PRECISION ELECTRONIC CORPORATION |
89372 | ROCKWELL INTERNATIONAL CORP NORTH AM |
99562 | MUELLER CO WESTERN DISTRICT SALES OF |
01843 | AMBAC INTERNATIONAL CORPORATION |
05157 | COHU INC. DBA COHU ELECTRONICS DIVIS |
13499 | ROCKWELL COLLINS INC. DBA GOVERNMENT |
57655 | NAUTEL MAINE INC. |
06481 | NORTHROP GRUMMAN GUIDANCE AND ELECTR |
37695 | RAYTHEON COMPANY DBA RAYTHEON |
02032 | HOLLINGSWORTH JOHN R CO |
24655 | GENRAD INC |
40608 | MILLER ELECTRIC MFG CO |
12697 | CLAROSTAT SENSORS AND CONTROLS |
96214 | RAYTHEON COMPANY |
K4241 | INDUSTRIAL POWER UNITS LTD |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAP | MOUNTING BUSHING LENGTH | 0.344 INCHES MINIMUM AND 0.390 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.468 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 1.515 INCHES MAXIMUM |
AAPN | SECTION QUANTITY | 1 |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
AJYP | SCREW THREAD SERIES DESIGNATOR | UNEF |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-94 SPECIFICATION |
AEFK | MAXIMUM STARTING TORQUE | 6.00 INCH-OUNCES |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 5.0 KILOHMS SINGLE SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 120.0 SINGLE SECTION |
AEFN | NONTURN DEVICE LOCATION | AT 9 OCLOCK |
AEFP | NONTURN DEVICE RADIUS | 0.515 INCHES MINIMUM AND 0.547 INCHES MAXIMUM |
APXH | TERMINAL LOCATION | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE |
ABPM | BODY DIAMETER | 1.032 INCHES MINIMUM AND 1.156 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABXF | SHAFT LENGTH | 0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUM |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 2.0 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 TAB, SOLDER LUG |
AAQL | BODY STYLE | CYLINDRICAL BUSHING MOUNTED |
AJYQ | SCREW THREAD QUANTITY PER INCH | 32.0 |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-94/5 GOVERNMENT SPECIFICATION |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFM | MAXIMUM STOP TORQUE | 128.00 INCH-OUNCES |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 309.0 MINIMUM AND 320.0 MAXIMUM |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AXGY | MOUNTING METHOD | STANDARD BUSHING |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
ABWV | SHAFT DIAMETER | 0.248 INCHES MINIMUM AND 0.251 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 1.312 INCHES MINIMUM AND 1.562 INCHES MAXIMUM |
AJYN | SCREW THREAD DIAMETER | 0.375 INCHES NOMINAL |