Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
RESISTOR , FIXED , WIRE WOUND , INDUCT

Definition:

INC 37403 REINSTATED ON 010303~A RESISTOR WHOSE OHMIC VALUE CANNOT BE ADJUSTED OR VARIED. THE RESISTANCE ELEMENT CONSISTS OF HIGH RESISTANCE WIRE (OR RIBBON) EITHER WOUND ON AN INSULATED FORM OR CONSTRUCTED SO AS TO BE SELF-SUPPORTING. THE ITEM MUST HAVE INHERENT CHARACTERISTICS OF INDUCING SELF-INDUCTANCE. OPPOSITION TO CURRENT FLOW IS AN INHERENT PROPERTY OF THE RESISTANCE WIRE AND IS MANIFESTED BY THE HEAT DISSIPATION IN THE RESISTOR. EXCLUDES SUPPRESSOR, IGNITION INTERFERENCE. SEE ALSO RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
747-5493-000 95105 A C 1 5 TX AF
RW67V470 81349 M 2 2 E TX
747-5493-000 13499 A C 1 5 TX AF
RW69V470 81349 M C 1 6 ZZ AC
MIL-R-26/4 81349 M 4 1 E TX
VBE609V47E H0203 A 5 2 5 ZG
TS547.5J 15915 A C 1 9 TU AB
352250000208 H0203 A 5 2 5 ZG

CAGE Information

Code Company
13499 ROCKWELL COLLINS INC. DBA GOVERNMENT
95105 ROCKWELL COLLINS INC. DIV GOVERNMENT
81349 MILITARY SPECIFICATIONS PROMULGATED
H0203 THALES NEDERLAND
15915 TEPRO OF FLORIDA INC.

Federal Supply Class

Title

RESISTORS

Inclusions:

INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.

Exclusions:

EXCLUDES RESISTANCE WIRE.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-R-26/4 GOVERNMENT SPECIFICATION
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-R-26/4 GOVERNMENT SPECIFICATION
CBME CUBIC MEASURE (NON-CORE) 0.100 CUBIC INCHES
ABPM BODY DIAMETER 0.250 INCHES MINIMUM AND 0.376 INCHES MAXIMUM
AAQZ INCLOSURE METHOD ENCAPSULATED
AAQG AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 350.0
AARG RELIABILITY INDICATOR NOT ESTABLISHED
TEST TEST DATA DOCUMENT 81349-MIL-R-26 SPECIFICATION
AAQF AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 25.0
STYL STYLE DESIGNATOR AXIAL TERMINAL EACH END
AAPP ELECTRICAL RESISTANCE 47.000 OHMS
ADAQ BODY LENGTH 0.906 INCHES MINIMUM AND 1.094 INCHES MAXIMUM
PKWT UNPACKAGED UNIT WEIGHT 5.0 GRAMS
AEFB POWER DISSIPATION RATING IN WATTS 6.500 FREE AIR
AARB TERMINAL TYPE WIRE LEAD
AAPQ RESISTANCE TOLERANCE IN PERCENT -5.000/+5.000
AAPE TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -260.0/+260.0
ABJT TERMINAL LENGTH 1.375 INCHES MINIMUM AND 2.125 INCHES MAXIMUM
AAQH TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0/+350.0

Similar Parts

747-5493-000 , 7475493000 , 5905-00-087-7157 , 5905000877157 , 000877157 , 747-5493-000 , RW67V470 , 747-5493-000 , RW69V470 , MIL-R-26/4 , VBE609V47E , TS547.5J , 352250000208 ,