National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RESISTOR , FIXED , WIRE WOUND , NONIND
Definition:
INC 37404 REINSTATED ON 010303~A RESISTOR WHOSE OHMIC VALUE CANNOT BE ADJUSTED OR VARIED. THE RESISTANCE ELEMENT CONSISTS OF HIGH RESISTANCE WIRE (OR RIBBON) EITHER WOUND ON AN INSULATED FORM OR CONSTRUCTED SO AS TO BE SELF-SUPPORTING. THE ITEMS MUST HAVE INHERENT CHARACTERISTICS OF INDUCING LITTLE OR NO SELF-INDUCTANCE. OPPOSITION TO CURRENT FLOW IS AN INHERENT PROPERTY OF THE RESISTANCE WIRE AND IS MANIFESTED BY THE HEAT DISSIPATION IN THE RESISTOR. EXCLUDES SUPPRESSOR, IGNITION INTERFERENCE. SEE ALSO RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
MIL-R-39009/1 | 81349 | M | 4 | 1 | 3 | TX | ||
RER75F9R53R | 81349 | M | 2 | 2 | 3 | TX | ||
RER75F9R53M | 81349 | M | 5 | 9 | 3 | TX | ||
RER75F9R53P | 81349 | M | 5 | 9 | 3 | TX |
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAU | BODY HEIGHT | 0.625 INCHES NOMINAL |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0/+50.0 |
AFWW | TERMINAL WIDTH | 0.140 INCHES MINIMUM |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
BYML | MOUNTING HOLE SIZE | 0.125 INCHES NOMINAL |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
ADAQ | BODY LENGTH | 1.938 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.438 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL (S) |
AAQZ | INCLOSURE METHOD | ENCASED |
ADAT | BODY WIDTH | 0.594 INCHES NOMINAL |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+275.0 |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000/+1.000 |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39009 SPECIFICATION |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.562 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 10.000 FREE AIR |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39009/1 GOVERNMENT SPECIFICATION |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AAPP | ELECTRICAL RESISTANCE | 9.530 OHMS |
AARB | TERMINAL TYPE | TAB, SOLDER LUG |