National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
FILTER , RADIO FREQUENCY INTERFERE
Definition:
AN ITEM DESIGNED TO SUPPRESS UNDESIRED (INTERFERING) FREQUENCIES AND HAVE A MINIMAL EFFECT ON THE DESIRED FREQUENCIES WHEN INSERTED IN AN ELECTRICAL POWER CIRCUIT. EXCLUDES ITEMS WHICH CONSIST OF A SINGLE CAPACITOR, INDUCTOR, RESISTOR, OR DEVICES CONSISTING OF ONLY TWO OR MORE CIRCUIT ELEMENTS OF THE SAME BASIC NAME. EXCLUDES FILTER, LOW PASS AND SUPPRESSOR, IGNITION INTERFERENCE. FOR ITEMS DESIGNED TO BE INSERTED IN A LINE WHICH IS PRIMARILY INTENDED TO CARRY HIGH FREQUENCY WAVES MODULATED WITH SIGNALS, SUCH AS ANTENNA LEAD-IN, SEE FILTER, BAND SUPPRESSION AND FILTER, BAND PASS. SEE ALSO LIMITER, ELECTRICAL NOISE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
200-0039 | 52151 | A | 5 | 2 | 2 | XG | ||
RF760 | 13619 | A | 3 | 9 | 6 | XG | ||
RF00760 | 13619 | A | C | 1 | 5 | ZZ | 9X |
CAGE Information
Code | Company |
---|---|
13619 | RFI CORPORATION |
52151 | CONTINENTAL ELECTRONICS CORPORATION |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
ADAQ | BODY LENGTH | 6.440 INCHES MINIMUM AND 6.560 INCHES MAXIMUM |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD OUTPUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
CQJX | NOMINAL THREAD SIZE | 1.125 INCHES |
ABHP | OVERALL LENGTH | 8.440 INCHES NOMINAL |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS SPRAYED ANY ACCEPTABLE AND 600.0 VOLTS 9TH BAND SUPPRESSION ANY ACCEPTABLE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNEF |
ADAR | BODY OUTSIDE DIAMETER | 2.235 INCHES MINIMUM AND 2.265 INCHES MAXIMUM |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD INPUT |
AKNA | INCLOSURE TYPE | ENCASED |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC BLANK AND 6.0 VOLTS DC BLANK |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 BLANK |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 BLANK |