National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
FUSE , CARTRIDGE
Definition:
A FUSE IN WHICH THE ELEMENT IS INCLOSED IN A CYLINDRICAL BODY. THE ELEMENT MAY BE RENEWABLE. THE TERMINALS MAY BE OF VARYING TYPES. IT MAY CONTAIN A VISUAL INDICATION THAT THE FUSIBLE ELEMENT IS SEVERED, AND MAY ALSO PROVIDE AN AUDIBLE ALARM THROUGH AUXILIARY CIRCUITRY. FOR NONCYLINDRICAL ITEMS, SEE FUSE, INCLOSED LINK.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
F09B250V4AS | 81348 | M | C | 1 | 6 | ZZ | AC | |
352250005462 | H0203 | A | 5 | 2 | 3 | ZG | ||
VBE860-9B4K | H0203 | A | 5 | 2 | 1 | ZG | ||
MIL-PRF-15160/9 | 81349 | M | 4 | 1 | E | ZZ | ||
F09B250V4AS | 81349 | M | 2 | 2 | 3 | TX |
CAGE Information
Code | Company |
---|---|
81348 | FEDERAL SPECIFICATIONS PROMULGATED B |
H0203 | THALES NEDERLAND |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
FUSES, ARRESTORS, ABSORBERS, AND
Inclusions:
INCLUDES FUSEHOLDERS; FUSE BOXES; FUSE POSTS; FUSE LINKS; FUSE BLOCKS; CURRENT LIMITERS; CORONA BALLS; ELECTROSTATIC DISCHARGERS.
Exclusions:
EXCLUDES CIRCUIT BREAKERS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAV | OVERALL DIAMETER | 0.402 INCHES MINIMUM AND 0.410 INCHES MAXIMUM |
ADTV | CASE MATERIAL | FIBER |
ABDN | TERMINAL SURFACE TREATMENT | SILVER PLATED |
ABHP | OVERALL LENGTH | 1.469 INCHES MINIMUM AND 1.531 INCHES MAXIMUM |
TEST | TEST DATA DOCUMENT | 81349-MIL-F-15160 SPECIFICATION |
CSQN | SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS | 10000.0 |
AFXE | MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC AND 250.0 DC |
CBBL | FEATURES PROVIDED | NONRENEWABLE FUSIBLE ELEMENT |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-F-15160/9C GOVERNMENT SPECIFICATION |
AAQL | BODY STYLE | TUBE TYPE |
AEBJ | CONTINUOUS CURRENT RATING IN AMPS | 4.000 |
AFXH | INTERRUPTION INDICATOR METHOD | OPAQUE BODY |
AFXF | CIRCUIT OVER-CURRENT INTERRUPTION TYPE | TIME DELAY |
CQPB | CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS | 12.0 200 PCT OF CURRENT RATING |