National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
ARRESTER , LIGHTNING
Definition:
A PROTECTIVE DEVICE TO PROVIDE A DISCHARGE PATH FOR LIGHTNING BETWEEN LINE AND LINE, AND/OR LINE AND GROUND. SEE ALSO PROTECTOR, TELEPHONE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
PMT3-310-400-10 | 71482 | R | 5 | 9 | 5 | TX | ||
PMT3-310-400-10 | 1E9M5 | A | 5 | 2 | 5 | ZZ | ||
SM-C-938073 | 80063 | A | 3 | 2 | 1 | TX |
CAGE Information
Code | Company |
---|---|
1E9M5 | C P CLARE CORP |
71482 | CP CLARE CORP NORTH AMERICAN SALES O |
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
Federal Supply Class
Title
FUSES, ARRESTORS, ABSORBERS, AND
Inclusions:
INCLUDES FUSEHOLDERS; FUSE BOXES; FUSE POSTS; FUSE LINKS; FUSE BLOCKS; CURRENT LIMITERS; CORONA BALLS; ELECTROSTATIC DISCHARGERS.
Exclusions:
EXCLUDES CIRCUIT BREAKERS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AQAQ | BREAKDOWN VOLTAGE | 1.000 KILOVOLTS MINIMUM AND 1.600 KILOVOLTS MAXIMUM |
ABHP | OVERALL LENGTH | 0.518 INCHES MAXIMUM |
ADJH | MOUNTING METHOD | TERMINAL |
ALGC | MOUNTING CONFIGURATION | TWO NICKEL-CLAD COPPER LEADS 0.256 IN. LONG; 0.040 IN. DIAMETER SPACED 0.374 IN. APART C TO C |
ADAV | OVERALL DIAMETER | 0.325 INCHES MAXIMUM |
AQAR | LINE TO GROUND VOLTAGE | 300.000 VOLTS MINIMUM AND 500.000 VOLTS MAXIMUM |
ALBY | USAGE DESIGN | INDOOR AND OUTDOOR |
AARB | TERMINAL TYPE | WIRE LEAD |
AARA | TERMINAL QUANTITY | 3 |
AAFZ | BODY MATERIAL | CERAMIC AND METAL |
AQAP | ARRESTER TYPE | GAS |