National Stock Number (NSN) Output Data
Definition:
AN ITEM SPECIFICALLY DESIGNED TO ABSORB AND CONSUME SURGES OF VOLTAGE SUCH AS THAT RESULTING ACROSS CONTACTS WHEN BREAKING A CIRCUIT HAVING AN INDUCTIVE LOAD OR A BURST OF STATIC ACROSS A TELEPHONE RECEIVER. IT IS CONNECTED IN PARALLEL WITH THE ITEM IT IS PROTECTING. IT MAY BE MADE UP OF METALLIC RECTIFIER CELLS OR SEMICONDUCTOR DEVICES CONNECTED BACK-TO-BACK WHICH MAY OR MAY NOT BE SHUNTED BY A CAPACITOR. IT MAY ALSO BE A SINGLE RECTIFIER CELL OR SEMICONDUCTOR DEVICE SHUNTED BY A CAPACITOR. EXCLUDES METALLIC RECTIFIERS WHICH ARE RATED FOR RECTIFYING CAPABILITIES AND ALL SINGLE UNIT SEMICONDUCTOR DEVICES NOT SHUNTED BY A CAPACITOR. FOR ITEMS PERFOMING THIS FUNCTION BY USE OF VOLTAGE SENSITIVE RESISTORS, SEE RESISTOR, VOLTAGE SENSITIVE. SEE ALSO CUTOUT DISK, PROTECTIVE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
6RS21SA10D10 | 09019 | F | 5 | 9 | 6 | TX | ||
6RS21SA10D10 | 81483 | A | C | 1 | 6 | ZZ | AC | |
14-236-349-00-018 | 92392 | H | 5 | 9 | 6 | TX | ||
6RS21SA1DD10 | 03497 | A | C | 1 | 6 | ZZ | AC | |
SD1854-10 | 59656 | A | 3 | 2 | 6 | TX | ||
2KVC26-10A10-ZS | 51589 | F | 5 | 9 | 6 | TX |
CAGE Information
Code | Company |
---|---|
03497 | GENERAL ELECTRIC CO OUTDOOR BREAKER |
09019 | GENERAL ELECTRIC CO POWER ELECTRONIC |
81483 | INTERNATIONAL RECTIFIER CORPORATION |
92392 | ALLIS-CHALMERS CORP |
59656 | DEAN TECHNOLOGY INC. DBA CKE |
51589 | ST-SEMICON INC |
Federal Supply Class
Title
FUSES, ARRESTORS, ABSORBERS, AND
Inclusions:
INCLUDES FUSEHOLDERS; FUSE BOXES; FUSE POSTS; FUSE LINKS; FUSE BLOCKS; CURRENT LIMITERS; CORONA BALLS; ELECTROSTATIC DISCHARGERS.
Exclusions:
EXCLUDES CIRCUIT BREAKERS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AARB | TERMINAL TYPE | SOLDER LUG |
AQCW | ELEMENT MATERIAL | SILICON CARBIDE |
AQDN | PROTECTED ITEM NAME | SILICON RECTIFIER |
AMPS | CURRENT RATING IN AMPS | 3.0 |
APZX | PROTECTIVE COVERING TYPE | FINISH |
ELEC | VOLTAGE IN VOLTS | 250.0 |
AQAY | CURRENT INTERRUPTING CAPACITY | 12.0 AMPERES MAXIMUM |
ALGC | MOUNTING CONFIGURATION | ONE BOLT 2.250 IN. LONG WITH THREADED STUD ENDS HAVING 0.164-32 THREADS PER IN.-AXIALLY LOCATED |
ALPY | POLARIZATION FEATURE | INCLUDED |
AARA | TERMINAL QUANTITY | 2 |
ACKG | COVERING MATERIAL | ENAMEL |
FREQ | FREQUENCY IN HERTZ | 40.0 |
ADJH | MOUNTING METHOD | THROUGH BOLT |
ACDC | CURRENT TYPE | AC |
ABHP | OVERALL LENGTH | 2.250 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 1.688 INCHES NOMINAL |
AQCT | SHUNT CAPACITOR | NOT INCLUDED |