National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
Reference/Part Number
CAGE Information
Code |
Company |
10001 |
NAVAIR AND NAVSEA MANAGED ORIGINAL D |
74193 |
EATON CORP HEINEMANN PRODUCTS COMMER |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
AJEC |
BOSS HEIGHT |
0.150 INCHES NOMINAL |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
AKPX |
POLE QUANTITY |
3 |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.471 INCHES NOMINAL |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1500.0 AC ALL LOCATIONS |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT AND MOISTURE RESISTANT |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.062 INCHES NOMINAL |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
5.0 AMPERES AC ALL LOCATIONS |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES NOMINAL |
ADAT |
BODY WIDTH |
2.265 INCHES NOMINAL |
ADAQ |
BODY LENGTH |
2.500 INCHES NOMINAL |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
10.000 NOMINAL AT 150 PCT ALL LOCATIONS AND 100.000 NOMINAL AT 100 PCT ALL LOCATIONS AND 1.000 NOMINAL AT 300 PCT ALL LOCATIONS |
ADTV |
CASE MATERIAL |
PLASTIC |
CPRQ |
RESET METHOD |
MANUAL |
CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.938 INCHES NOMINAL |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
120.0 AC ALL LOCATIONS |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 THREADED STUD |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES NOMINAL |
Similar Parts